Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 40 - Protection of Environment |
Chapter I - Environmental Protection Agency |
SubChapter D - Water Programs |
Part 141 - National Primary Drinking Water Regulations |
Subpart C - Monitoring and Analytical Requirements |
§ 141.25 - Analytical methods for radioactivity.
-
§ 141.25 Analytical methods for radioactivity.
((a) Analysis for the following contaminants shall be conducted to determine compliance with § 141.66 (radioactivity) in accordance with the methods in the following table, or the alternative methods listed in appendix A to subpart C this part, or their equivalent determined by EPA in accordance with § 141.27.
Alternative Testing Methods for Contaminants Listed at 40 CFR 141.25(a)
Contaminant Methodology EPA method SM 21st edition1 SM 22nd edition,28 SM 23rd edition,49 SM 24th edition66 ASTM4 SM online3 Contaminant Methodology Reference (Method of Page Number) EPA1 EPA2 EPA3 EPA4 SM5 ASTM6 USGS7 DOE8 Other Naturally Occurring: Gross alpha11 and beta Evaporation 900.0 , Revp. 1.050 00–01 p. 1 302, 7110 B 7110 B Liquid Scintillation 7110 D D 7283–17 7110 D–17. , 7110 B–00 R–1120–76 Gross alpha11 Coprecipitation 00–02 7110 C, 7110 C C–00 Radium 226 Radon emanation 903.1 , Rev. 1.0537500-Ra C 7500-Ra C D 3454–05, –18, D 3454–21 p. 16 Ra–04 p. 19 305, 7500–Ra C, 7500–Ra C–01 D3454–97 R–1141–76 Ra-04 NY9, Radiochemical 903.0 , Rev. 1.0547500-Ra B 7500-Ra B D 2460–07 Gamma Spectrometry 7500-Ra E 7500-Ra E–07. p. 13 Ra-03 304, 7500–Ra B, 7500–Ra B–01 D2460–97 R–1140–76 GA14 Radium 228 Radiochemical 904.0 , Rev. 1.0627500-Ra D 7500-Ra D Gamma Spectrometry 7500-Ra E 7500-Ra E–07. Uranium Radiochemical 7500–U B 7500–U B ICP–MS 3125 D 5673–05, 10, 16 Alpha spectrometry 7500–U C 7500–U C D 3972–09 Laser Phosphorimetry D 5174–07 Alpha Liquid Scintillation Spectrometry D 6239–09 p. 24 Ra-05 p. 19 7500–Ra D, 7500–Ra D–01 R–1142–76 NY9,
NJ10,
GA14Uranium12 Radiochemical 908.0 7500–U B, 7500–U B–00 Fluorometric 908.1 7500–U C (17th Ed.) D2907–97 R–1180–76, R–1181–76 U–04 ICP–MS 200.813 3125 D5673–03 Alpha Spectrometry 00–07 p. 33 7500–U C (18th, 19th, or 20th Ed.), 7500–U C–00 D3972–97, 02 R–1182–76 U–02 Laser Phosphorimetry D5174–97, 02 Man-Made: Radioactive Cesium Radiochemical 7500-Cs B 7500-Cs B 901.0 p. 4 7500–Cs B, 7500–Cs B–00 D2459–72 R–1111–76 Gamma Ray Spectrometry 7120 7120 D 3649–06 901.1 p. 92 7120, 7120–97 D3649–91, 98a R–1110–76 4.5.2.3 Radioactive Iodine Radiochemical 902.0 p. 6 7500–I B, 7500–I B–00 p. 9 7500–I C, 7500–I C–00 7500–I D7500–I B, 7500–I C, 7500–I D D 3649–06 D–00 D3649–91, 98a Gamma Ray Spectrometry 7120 7120 D 4785–08, –20 901.1 p. 92 7120, 7120–97 D4785–93, 00a 4.5.2.3 Radioactive Strontium 89, 90 Radiochemical 7500-Sr B 7500-Sr B Tritium Liquid Scintillation 7500-3H B 7500-3H B D 4107–08, –20 905.0 p. 29 Sr–04 p. 65 303, 7500–Sr B, 7500–Sr B–01 R–1160–76 Sr–01, Sr–02 Tritium Liquid Scintillation 906.0 p. 34 H–02 p. 87 306, 7500–3 H B, 7500–3 H B–00 D4107–91, 98 (Reapproved 2002) R–1171–76 Gamma Emitters Gamma Ray Spectrometry 7120, 7500-Cs B, 7500–I B 7120, 7500-Cs B, 7500–I B D 3649–06, D 4785–08, –20 901.1 p. 92 7120, 7120–97 D3649–91, 98a R–1110–76 Ga–01–R 902.0 7500–Cs B, 7500–Cs B–00 D4785–93, 00a 901.0 7500–I B, 7500–I B–00 (b) When the identification and measurement of radionuclides other than those listed in paragraph (a) of this section is required, the following references are to be used, except in cases where alternative methods have been approved in accordance with § 141.27.
(1) Procedures for Radiochemical Analysis of Nuclear Reactor Aqueous Solutions, H. L. Krieger and S. Gold, EPA-R4–73–014. USEPA, Cincinnati, Ohio, May 1973.
(2) HASL Procedure Manual, Edited by John H. Harley. HASL 300, ERDA Health and Safety Laboratory, New York, NY., 1973.
(c) For the purpose of monitoring radioactivity concentrations in drinking water, the required sensitivity of the radioanalysis is defined in terms of a detection limit. The detection limit shall be that concentration which can be counted with a precision of plus or minus 100 percent at the 95 percent confidence level (1.96σ where σ is the standard deviation of the net counting rate of the sample).
(1) To determine compliance with § 141.66(b), (c), and (e) the detection limit shall not exceed the concentrations in Table B to this paragraph.
Table B—Detection Limits for Gross Alpha Particle Activity, Radium 226, Radium 228, and Uranium
Contaminant Detection
limitGross alpha particle activity 3 pCi/L. Radium 226 1 pCi/L. Radium 228 1 pCi/L. Uranium 1 µg/L (2) To determine compliance with § 141.66(d) the detection limits shall not exceed the concentrations listed in Table C to this paragraph.
Table C—Detection Limits for Man-made Beta Particle and Photon Emitters
Radionuclide Detection limit Tritium 1,000 pCi/1. Strontium–89 10 pCi/1. Strontium–90 2 pCi/1. Iodine–131 1 pCi/1. Cesium–134 10 pCi/1. Gross beta 4 pCi/1. Other radionuclides 1⁄10 of the applicable limit. (d) To judge compliance with the maximum contaminant levels listed in § 141.66, averages of data shall be used and shall be rounded to the same number of significant figures as the maximum contaminant level for the substance in question.
(e) The State has the authority to determine compliance or initiate enforcement action based upon analytical results or other information compiled by their sanctioned representatives and agencies.
[41 FR 28404, July 9, 1976, as amended at 45 FR 57345, Aug. 27, 1980; 62 FR 10173, Mar. 5, 1997; 65 FR 76745, Dec. 7, 2000; 67 FR 65250, Oct. 23, 2002; 69 FR 38855, June 29, 2004; 69 FR 52180, Aug. 25, 2004; 72 FR 11245, Mar. 12, 2007; 74 FR 30958, June 29, 2009; 89 FR 5779, Jan. 30, 2024]