§ 98.306 - Data reporting requirements.
-
§ 98.306 Data reporting requirements.
In addition to the information required by § 98.3(c), each annual report must contain the following information for each electric power system, by chemical:
(a) Nameplate capacity of equipment (pounds) containing SF6 and nameplate capacity of equipment (pounds) containing each PFC:
(1) Existing at the beginning of the year (excluding hermetically sealed-pressure switchgear).
(2) New hermetically sealed-pressure switchgear during the year (all SF6-insulated equipment, including .
)(3) New equipment other than hermetically sealed-pressure switchgear
during the year.
3(
(all SF6-insulated equipment, including4) Retired hermetically sealed-pressure switchgear during the year
.
)(5) Retired equipment other than hermetically sealed-pressure switchgear
during the year.
(b) Transmission miles (length of lines carrying voltages above 35 kilovoltkilovolts).
(c) Distribution miles (length of lines carrying voltages at or below 35 kilovoltkilovolts).
(d) Pounds of SF6 and PFC stored in containers, but not in energized equipment, at the beginning of the year.
(e) Pounds of SF6 and PFC stored in containers, but not in energized equipment, at the end of the year.
(f) Pounds of SF6 and PFC purchased in bulk from chemical producers or distributors.
(g) Pounds of SF6 and PFC purchased from equipment manufacturers or distributors with or inside equipment, including hermetically sealed-pressure switchgear.
(h) Pounds of SF6 and PFC returned to facility after off-site recycling.
(i) Pounds of SF6 and PFC in bulk and contained in equipment sold to other entities.
(j) Pounds of SF6 and PFC returned to suppliers.
(k) Pounds of SF6 and PFC sent off-site for recycling.
(l) Pounds of SF6 and PFC sent off-site for destruction.
(m) State(s) or territory in which the facility lies.
(n) The number of SF6- or PFC-containing pieces of equipment in each of the following equipment categories:
(1) New hermetically sealed-pressure switchgear during the year.
(2) New equipment other than hermetically sealed-pressure switchgear during the year.
(3) Retired hermetically sealed-pressure switchgear during the year.
(4) Retired equipment other than hermetically sealed-pressure switchgear during the year.
[74 FR 56374, Oct. 30, 2009, as amended at 81 FR 89264, Dec. 9, 2016]