§ 98.66 - Data reporting requirements.  


Latest version.
  • § 98.66 Data reporting requirements.

    In addition to the information required by § 98.3(c), you must report the following information at the facility level:

    (a) [Reserved]

    (b) Type of smelter technology used.

    (c) The following PFC-specific information on an annual basis:

    (1) Perfluoromethane emissions and perfluoroethane emissions from anode effects in all prebake and all Søderberg electrolysis cells combined.

    (2) [Reserved]

    (3) The

    Anode effect minutes per cell-day (AE-mins/cell-day), anode effect frequency (AE/cell-day), anode effect duration (minutes). (Or anode effect overvoltage factor ((kg CF4/metric ton Al)/(mV/cell day)), potline overvoltage (mV/cell day), current efficiency (%)).

    (3) Smelter-specific slope coefficients (or overvoltage emission factors) and the last date when the smelter-specific - slope coefficients (or overvoltage emission factors) were measured.

    (d) Method used to measure the frequency and duration of anode effects (or overvoltage).

    (e) The following CO2-specific information for prebake cells:

    (1) Annual anode consumption if using the method in § 98.63(g).

    (2) Annual CO2 emissions from the smelter.

    (f) The following CO2-specific information for Søderberg cells:

    (1) Annual paste consumption if using the method in § 98.63(g).

    (2) Annual CO2 emissions from the smelter.

    (g) [Reserved]

    (h) Exact data elements required will vary depending on smelter technology (e.g., point-feed prebake or Søderberg) and process control technology (e.g., Pechiney or other).

    [74 FR 56374, Oct. 30, 2009, as amended at 75 FR 79156, Dec. 17, 2010; 79 FR 63784, Oct. 24, 2014; 81 FR 89253, Dec. 9, 2016]