§ 3175.119 - Components to analyze.  


Latest version.
  • § 3175.119 Components to analyze.

    (a) The gas must be analyzed for the following components:

    (1) Methane;

    (2) Ethane;

    (3) Propane;

    (4) Iso Butane;

    (5) Normal Butane;

    (6) Pentanes;

    (7) Hexanes + (C6+);

    (8) Carbon dioxide; and

    (9) Nitrogen.

    (b) When the concentration of C6+ exceeds 0.5 mole percent, the following gas components must also be analyzed:

    (1) Hexanes;

    (2) Heptanes;

    (3) Octanes; and

    (4) Nonanes +.

    (c) In lieu of testing each sample for the components required under paragraph (b) of this section, the operator may periodically test for these components and adjust the assumed C6+ composition to remove bias in the heating value (see § 3175.126(a)(3)). The C6+ composition must be applied to the mole percent of C6+ analyses until the next analysis is done under paragraph (b) of this section. The minimum analysis frequency for the components listed in paragraph (b) of this section is as follows:

    (1) For high-volume FMPs, once per year; and

    (2) For very-high-volume FMPs, once every 6 months.