§ 62.10-1 - Definitions.
-
§ 62.10-1 Definitions.
(a)For the purpose of this part:
Alarm means an audible and visual indication of a hazardous or potentially hazardous condition that requires attention.
Automated means the use of automatic or remote control, instrumentation, or alarms.
Automatic control means self-regulating in attaining or carrying out an operator-specified equipment response or sequence.
Boiler low-low water level is the minimum safe level in the boiler, in no case lower than that visible in the gage glass (see § 52.01-110 of this chapter, Water Level Indicatorssubchapter).
Engineering Control Center (ECC) means the centralized engineering control, monitoring, and communications location.
Failsafe means that upon failure or malfunction of a component, subsystem, or system, the output automatically reverts to a pre-determined design state of least critical consequence. Typical failsafe states are listed in Table 62.10-1(a).
Table 62.10-1(a)—Typicalthe following table:
Typical Failsafe States
System or component Preferred failsafe state (1) Cooling water valve As is or open. (2) Alarm system Annunciate. (3) Safety system Shut down, limited, or as is & alarm. (4) Burner valve Closed. (5) Propulsion speed control As is. (6) Feedwater valve As is or open. (7) Controllable pitch propeller As is. (8) Propulsion safety trip As is & alarm. (9) Fuel tank valve See § 56.50-60(d) of this subchapter. Flooding safety refers to flooding detection, watertight integrity, and dewatering systems.
Independent refers to equipment arranged to perform its required function regardless of the state of operation, or failure, of other equipment.
Limit control means a function of an automatic control system to restrict operation to a specified operating range or sequence without stopping the machinery.
Local control means operator control from a location where the equipment and its output can be directly manipulated and observed, e.g., at the switchboard, motor controller, propulsion engine, or other equipment.
Manual control means operation by direct or power-assisted operator intervention.
Monitor means the use of direct observation, instrumentation, alarms, or a combination of these to determine equipment operation.
Remote control means non-local automatic or manual control.
Safety trip control system means a manually or automatically operated system that rapidly shuts down another system or subsystem.
System means a grouping or arrangement of elements that interact to perform a specific function and typically includes the following, as applicable:
(1) A fuel or power source.
(2) Power conversion elements.
(3) Control elements.
(4) Power transmission elements.
(5) Instrumentation.
(6) Safety control elements.
(7) Conditioning elements.
Vital system or equipment is essential to the safety of the vessel, its passengers and crew. This typically includes, but is not limited to, the following:
(1) Fire detection, alarm, and extinguishing systems.
(2) Flooding safety systems.
(3) Ship service and emergency electrical generators, switchgear, and motor control circuits serving vital electrical loads.
(4) The emergency equipment and systems listed in § 112.15 of this chapter.
(5) Propulsion systems, including those provided to meet § 58.01-35 of this subchapter.
(6) Steering systems.