§ 238.223 - Locomotive fuel tanks.  


Latest version.
  • § 238.223 Locomotive fuel tanks.

    Locomotive fuel tanks shall comply with either the following or an industry standard providing at least an equivalent level of safety if approved by FRA under § 238.21:

    (a) External fuel tanks. External locomotive fuel tanks shall comply with the requirements contained in Appendix D to this part.

    (b) Internal fuel tanks.

    (1) Internal locomotive fuel tanks shall be positioned in a manner to reduce the likelihood of accidental penetration from roadway debris or collision.

    (2) Internal fuel tank vent systems shall be designed so they do not become a path of fuel loss in any tank orientation due to a locomotive overturning.

    (3) Internal fuel tank bulkheads and skin shall, at a minimum, be equivalent to a 5/16-inch thick steel plate with a yield strength of 25,000 pounds per square inch. Material of a higher yield strength may be used to decrease the required thickness of the material provided at least an equivalent level of strength is maintained. Skid plates are not required.

    [67 FR 19991, Apr. 23, 2002]