§ 63.1221 - What are the replacement standards for hazardous waste burning lightweight aggregate kilns?


Latest version.
  • § 63.1221 What are the replacement standards for hazardous waste burning lightweight aggregate kilns?

    (a) Emission and hazardous waste feed limits for existing sources. You must not discharge or cause combustion gases to be emitted into the atmosphere or feed hazardous waste that contain:

    (1) For dioxins and furans, either:

    (i) Emissions in excess of 0.20 ng TEQ/dscm corrected to 7 percent oxygen; or

    (ii) Rapid quench of the combustion gas temperature at the exit of the (last) combustion chamber (or exit of any waste heat recovery system that immediately follows the last combustion chamber) to 400 °F or lower based on the average of the test run average temperatures. You must also notify in writing the RCRA authority that you are complying with this option;

    (2) For mercury, either:

    (i) Emissions in excess of 120 µgm/dscm, corrected to 7 percent oxygen; or

    (ii) A hazardous waste feedrate corresponding to a maximum theoretical emission concentration (MTEC) in excess of 120 µgm/dscm;

    (3) For cadmium and lead, both:

    (i) Emissions in excess of 3.0 × 10−4 lbs combined emissions of cadmium and lead attributable to the hazardous waste per million Btu heat input from the hazardous waste; and

    (ii) Emissions in excess of 250 µgm/dscm, combined emissions, corrected to 7 percent oxygen;

    (4) For arsenic, beryllium, and chromium, both:

    (i) In excess of 9.5 × 10−5 lbs combined emissions of arsenic, beryllium, and chromium attributable to the hazardous waste per million Btu heat input from the hazardous waste;

    (ii) Emissions in excess of 110 µgm/dscm, combined emissions, corrected to 7 percent oxygen;

    (5) Carbon monoxide and hydrocarbons.

    (i) Carbon monoxide in excess of 100 parts per million by volume, over an hourly rolling average (monitored continuously with a continuous emissions monitoring system), dry basis and corrected to 7 percent oxygen. If you elect to comply with this carbon monoxide standard rather than the hydrocarbon standard under paragraph (a)(5)(ii) of this section, you also must document that, during the destruction and removal efficiency (DRE) test runs or their equivalent as provided by § 63.1206(b)(7), hydrocarbons do not exceed 20 parts per million by volume during those runs, over an hourly rolling average (monitored continuously with a continuous emissions monitoring system), dry basis, corrected to 7 percent oxygen, and reported as propane; or

    (ii) Hydrocarbons in excess of 20 parts per million by volume, over an hourly rolling average, dry basis, corrected to 7 percent oxygen, and reported as propane;

    (6) Hydrogen chloride and chlorine gas in excess of 600 parts per million by volume, combined emissions, expressed as a chloride (Cl(−)) equivalent, dry basis and corrected to 7 percent oxygen; and

    (7) Particulate matter emissions in excess of 0.025 gr/dscf, corrected to 7 percent oxygen.

    (b) Emission and hazardous waste feed limits for new sources. You must not discharge or cause combustion gases to be emitted into the atmosphere or feed hazardous waste that contain:

    (1) For dioxins and furans, either:

    (i) Emissions in excess of 0.20 ng TEQ/dscm corrected to 7 percent oxygen; or

    (ii) Rapid quench of the combustion gas temperature at the exit of the (last) combustion chamber (or exit of any waste heat recovery system that immediately follows the last combustion chamber) to 400 °F or lower based on the average of the test run average temperatures. You must also notify in writing the RCRA authority that you are complying with this option;

    (2) For mercury, either:

    (i) Emissions in excess of 120 µgm/dscm, corrected to 7 percent oxygen; or

    (ii) A hazardous waste feedrate corresponding to a maximum theoretical emission concentration (MTEC) in excess of 120 µgm/dscm;

    (3) For cadmium and lead, both:

    (i) Emissions in excess of 3.7 × 10−5 lbs combined emissions of cadmium and lead attributable to the hazardous waste per million Btu heat input from the hazardous waste; and

    (ii) Emissions in excess of 43 µgm/dscm, combined emissions, corrected to 7 percent oxygen;

    (4) For arsenic, beryllium, and chromium, both:

    (i) In excess of 3.3 × 10−5 lbs combined emissions of arsenic, beryllium, and chromium attributable to the hazardous waste per million Btu heat input from the hazardous waste;

    (ii) Emissions in excess of 110 µgm/dscm, combined emissions, corrected to 7 percent oxygen;

    (5) Carbon monoxide and hydrocarbons.

    (i) Carbon monoxide in excess of 100 parts per million by volume, over an hourly rolling average (monitored continuously with a continuous emissions monitoring system), dry basis and corrected to 7 percent oxygen. If you elect to comply with this carbon monoxide standard rather than the hydrocarbon standard under paragraph (b)(5)(ii) of this section, you also must document that, during the destruction and removal efficiency (DRE) test runs or their equivalent as provided by § 63.1206(b)(7), hydrocarbons do not exceed 20 parts per million by volume during those runs, over an hourly rolling average (monitored continuously with a continuous emissions monitoring system), dry basis, corrected to 7 percent oxygen, and reported as propane; or

    (ii) Hydrocarbons in excess of 20 parts per million by volume, over an hourly rolling average, dry basis, corrected to 7 percent oxygen, and reported as propane;

    (6) Hydrogen chloride and chlorine gas in excess of 600 parts per million by volume, combined emissions, expressed as a chloride (Cl(−)) equivalent, dry basis and corrected to 7 percent oxygen; and

    (7) Particulate matter emissions in excess of 0.0098 gr/dscf corrected to 7 percent oxygen.

    (c) Destruction and removal efficiency (DRE) standard -

    (1) 99.99% DRE. Except as provided in paragraph (c)(2) of this section, you must achieve a destruction and removal efficiency (DRE) of 99.99% for each principal organic hazardous constituent (POHC) designated under paragraph (c)(3) of this section. You must calculate DRE for each POHC from the following equation:

    DRE = [1 − (Wout / Win)] × 100%

    Where:

    Win = mass feedrate of one POHC in a waste feedstream; and

    Wout = mass emission rate of the same POHC present in exhaust emissions prior to release to the atmosphere.

    (2) 99.9999% DRE. If you burn the dioxin-listed hazardous wastes F020, F021, F022, F023, F026, or F027 (see § 261.31 of this chapter), you must achieve a destruction and removal efficiency (DRE) of 99.9999% for each POHC that you designate under paragraph (c)(3) of this section. You must demonstrate this DRE performance on POHCs that are more difficult to incinerate than tetra-, penta-, and hexachlorodibenzo-dioxins and dibenzofurans. You must use the equation in paragraph (c)(1) of this section to calculate DRE for each POHC. In addition, you must notify the Administrator of your intent to burn hazardous wastes F020, F021, F022, F023, F026, or F027.

    (3) Principal organic hazardous constituents (POHCs).

    (i) You must treat each POHC in the waste feed that you specify under paragraph (c)(3)(ii) of this section to the extent required by paragraphs (c)(1) and (c)(2) of this section.

    (ii) You must specify one or more POHCs that are representative of the most difficult to destroy organic compounds in your hazardous waste feedstream. You must base this specification on the degree of difficulty of incineration of the organic constituents in the hazardous waste and on their concentration or mass in the hazardous waste feed, considering the results of hazardous waste analyses or other data and information.

    (d) Significant figures. The emission limits provided by paragraphs (a) and (b) of this section are presented with two significant figures. Although you must perform intermediate calculations using at least three significant figures, you may round the resultant emission levels to two significant figures to document compliance.

    [70 FR 59574, Oct. 12, 2005]