§ 250.867 - Temporary quarters and temporary equipment.  


Latest version.
  • § 250.867 Temporary quarters and temporary equipment.

    (a) The District Manager must approve all temporary quarters to be installed in production processing areas or other classified areas on OCS facilities. You must equip such temporary quarters with all safety devices required by API RP 14C, Appendix C (incorporated by reference as specified in § 250.198). The District Manager must approve the safety system/safety devices associated with the temporary quarters prior to installation.

    (b) The District Manager may require you to install a temporary firewater system for temporary quarters in production processing areas or other classified areas.

    (c) Temporary equipment associated with the production process system, including equipment used for well testing and/or well clean-up, must be approved by the District Manager.

    (d) The District Manager must approve temporary generators that would require a change to the electrical one-line diagram in § 250.842(a).

    [81 FR 60918, Sept. 7, 2016, as amended at 83 FR 49259, Sept. 28, 2018]