§ 1065.202 - Data updating, recording, and control.  


Latest version.
  • § 1065.202 Data updating, recording, and control.

    Your test system must be able to update data, record data and control systems related to operator demand, the dynamometer, sampling equipment, and measurement instruments. Set up the measurement and recording equipment to avoid aliasing by ensuring that the sampling frequency is at least double that of the signal you are measuring, consistent with good engineering judgment; this may require increasing the sampling rate or filtering the signal. Use data acquisition and control systems that can record at the specified minimum frequencies, as follows:

    Table 1 of § 1065.202 - Data Recording and Control Minimum Frequencies

    Applicable test protocol section Measured values Minimum
    command and control
    frequencya
    Minimum
    recording
    frequencybc
    § 1065.510 Speed and torque during an engine step-map 1 Hz 1 mean value per step.
    § 1065.510 Speed and torque during an engine sweep-map 5 Hz 1 Hz means.
    § 1065.514; § 1065.530 Transient duty cycle reference and feedback speeds and torques 5 Hz 1 Hz means.
    § 1065.514; § 1065.530 Steady-state and ramped-modal duty cycle reference and feedback speeds and torques 1 Hz 1 Hz.
    § 1065.520; § 1065.530; § 1065.550 Continuous concentrations of raw or dilute analyzers 1 Hz.
    § 1065.520; § 1065.530 § 1065.550 Batch concentrations of raw or dilute analyzers 1 mean value per test interval.
    § 1065.530; § 1065.545 Diluted exhaust flow rate from a CVS with a heat exchanger upstream of the flow measurement 1 Hz.
    § 1065.530; § 1065.545 Diluted exhaust flow rate from a CVS without a heat exchanger upstream of the flow measurement 5 Hz 1 Hz means.
    § 1065.530; § 1065.545 Intake-air or raw-exhaust flow rate 1 Hz means.
    § 1065.530; § 1065.545 Dilution air flow if actively controlled (for example, a partial-flow PM sampling system)d 5 Hz 1 Hz means.
    § 1065.530; § 1065.545 Sample flow from a CVS that has a heat exchanger 1 Hz 1 Hz.
    § 1065.530; § 1065.545 Sample flow from a CVS that does not have a heat exchanger 5 Hz 1 Hz means.

    [79 FR 23759, Apr. 28, 2014, as amended at 81 FR 74162, Oct. 25, 2016]