§ 111.30-19 - Buses and wiring.  


Latest version.
  • § 111.30-19 Buses and wiring.

    (a) General. Each bus must meet the requirements of either—

    (1) Section 75.10 of IEEE 45–1998 45.7–2012 (incorporated by reference; see 46 CFR § 110.10–110–1 of this subchapter); or

    (2) IEC 60092–302:1997 (clause 7) (incorporated by reference; see 46 CFR § 110.10–110–1 of this subchapter).

    (b) Wiring. Instrumentation and control wiring must be—

    (1) Suitable for installation within in a switchboard enclosure and be rated at 90 °C or higher;

    (2) Stranded copper;

    (3) No. 14 AWG (2.10 mm2) or larger or must be ribbon cable or similar conductor size cable recommended for use in low-power instrumentation, monitoring, or control circuits by the equipment manufacturer;

    (4) Flame-retardant meeting test VW–1 of ANSI/UL 1581 2556 or IEC 60332–1 (both 60332–1–1:2015 and IEC 60332–1–2:2015 (all incorporated by reference; see 46 CFR § 110.10–110–1 of this subchapter); and

    (5) Extra flexible, if used on a hinged panel.

    [CGD 94–108, 61 FR 28278, June 4, 1996, as amended at 62 FR 23908, May 1, 1997; USCG–2003–16630, 73 FR 65197, Oct. 31, 2008; USCG–2013–0671, 78 FR 60153, Sept. 30, 2013; USCG–2020–0075, 88 FR 16361, Mar. 16, 2023]