§ 111.75-20 - Luminaries (lighting fixtures).


Latest version.
  • § 111.75-20 Lighting Luminaries (lighting fixtures.

    ).

    (a) The construction of each luminaire (lighting fixture) for a non-hazardous location must meet ANSI/UL 1598A, or IEC 60092–306:2009 (both incorporated by reference; see 46 CFR § 110.10–110–1 of this subchapter).

    (b) Each fixture globe, lens, or diffuser must have a high strength guard or be made of high strength material, Nonemergency and inside-type decorative luminaires in environmentally protected, nonhazardous locations must meet the applicable luminaire-type requirements of ANSI/UL 1598 or IEC 60092–306:2009 (both incorporated by reference; see § 110.10–1 of this subchapter). These luminaires must also meet Clauses 7.4, 8.1, 8.3, 11.2, 13.4, and 17.2 of ANSI/UL 1598A (incorporated by reference; see § 110.10–1 of this subchapter), except in an accommodation space, navigating bridge, gyro room, radio room, galley, or similar space where it is not subject to damage.

    (c) No fixture may be used as a connection box for a circuit other than the branch circuit supplying the fixture.

    (d) Lighting fixtures must be installed as follows:

    (1)

    Each

    fixture in the weather or in a location exposed to splashing water must be watertight. Each fixture in a damp or wet location must at least be dripproof.

    (2) Each fixture and lampholder must be fixed. A fixture must not be supported by the screw shell of a lampholder.

    (3) Each pendent-type fixture must be suspended by and supplied through a threaded, rigid conduit stem.

    (4) Each

    tablelamp, desklamp, floorlamp, and similar equipment must be secured in place so that it cannot be displaced by the roll or pitch of the vessel.

    (e) Nonemergency and decorative interior-lighting fixtures in environmentally protected, nonhazardous locations need meet only the applicable UL type-fixture standards in UL 1598 (incorporated by reference; see 46 CFR 110.10–1) and UL 1598A marine supplement or the standards in IEC 60092–306 . These fixtures must have vibration clamps on fluorescent tubes longer than 102 cm (40 inches), secure mounting of glassware, and rigid mounting.

    [CGD 74–125A, 47 FR 15236, Apr. 8, 1982, as amended by CGD 94–108, 61 FR 28283, June 4, 1996; 61 FR 36787, July 12, 1996; 62 FR 23909, May 1, 1997; USCG–2003–16630, 73 FR 65199, Oct. 31, 2008; USCG–2013–0671, 78 FR 60153, Sept. 30, 2013[USCG–2020–0075, 88 FR 16365, Mar. 16, 2023]