Code of Federal Regulations (Last Updated: July 5, 2024) |
![]() |
Title 46 - Shipping |
![]() |
Chapter I - Coast Guard, Department of Homeland Security |
![]() |
SubChapter L - Offshore Supply Vessels |
![]() |
Part 129 - Electrical Installations |
![]() |
Subpart C - Power Sources and Distribution Systems |
§ 129.326 - Dual-voltage generators.
Latest version.
-
§ 129.326 Dual-voltage generators.
If a dual-voltage generator is installed on an OSV -
(a) The neutral of the dual-voltage system must be solidly grounded at the switchboard's neutral bus and be accessible for checking the insulation resistance of the generator; and
(b) Ground detection must be provided that -
(1) For an alternating-current system, complies with § 111.05-27 of this chapter; and
(2) For a direct-current system, complies with § 111.05-29 of this chapter.