    (a) This section contains requirements for test rigs used in approval testing of separators. A diagram of a typical test rig is shown in Figure 162.050-17(a).

    FIGURE 162.050-17(a) - SEPARATOR TEST RIG

    (b) Each mixture pump on a test rig must -

    (1) Be a centrifugal pump capable of operating at 1,000 revolutions per minute or more;

    (2) Have a delivery capacity of at least 1.5 times the maximum throughput at which the separator being tested is designed to operate;

    (3) Have a maximum delivery pressure that is equal to or greater than the maximum influent pressure at which the separator is designed to operate; and

    (4) Have either bypass piping to its suction side or a throttle valve or orifice on its discharge side.

    (c) The inlet piping of the test rig must be sized so that -

    (1) Influent water flows at a Reynolds Number of at least 10,000;

    (2) The influent flow rate is between one and three meters per second; and

    (3) Its length is at least 20 times its inside diameter.

    (d) Each sample point on a test rig must meet the design requirements described in Figure 162.050-17(d) and must be in a vertical portion of the test rig piping.

    FIGURE 162.050-17(d) - SAMPLE POINT