Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 46 - Shipping |
Chapter I - Coast Guard, Department of Homeland Security |
SubChapter V - Marine Occupational Safety and Health Standards |
Part 197 - General Provisions |
Subpart B - Commercial Diving Operations |
Equipment |
§ 197.334 - Open diving bells.
Latest version.
-
§ 197.334 Open diving bells.
Each open diving bell must -
(a) Have an upper section that provides an envelope capable of maintaining a bubble of breathing mixture available to a diver standing on the lower section of the platform with his body through the open bottom and his head in the bubble;
(b) Have lifting equipment capable of returning the occupied open bell to the dive location;
(c) Have an umbilical; and
(d) Be -
(1) Made of corrosion-resisting material; or
(2) Protected against and maintained free from injurious corrosion.