§ 35.30-30 - Portable electric equipment - TB/ALL.  


Latest version.
  • § 35.30-30 Portable electric equipment - TB/ALL.

    Portable electric equipment must not be used in a hazardous location described in subpart 111.105 of this chapter except:

    (a) Self-contained, battery-fed, explosion-proof lamps approved by Underwriters Laboratories Inc., Factory Mutual Research Corporation, or other independent laboratory recognized by the Commandant, for use in a Class I, Division 1 location for the electrical group classification of the cargo;

    (b) Intrinsically safe equipment approved by Underwriters Laboratories Inc., Factory Mutual Research Corporation, or other independent laboratory recognized by the Commandant, for use in a Class I, Division 1 location for the electrical group classification of the cargo; and

    (c) Any electrical equipment, if:

    (1) The hazardous location is:

    (i) Enclosed; and

    (ii) Gas free;

    (2) The adjacent compartments are:

    (i) Gas free;

    (ii) Inerted;

    (iii) Filled with water;

    (iv) Filled with Grade E liquid; or

    (v) Spaces where flammable gases are not expected to accumulate; and:

    (3) Each compartment where flammable gas is expected to accumulate is:

    (i) Closed; and

    (ii) Secured.

    [CGD 74-125A, 47 FR 15230, Apr. 8, 1982]