§ 192.105 - Design formula for steel pipe.  


Latest version.
  • § 192.105 Design formula for steel pipe.

    (a) The design pressure for steel pipe is determined in accordance with the following formula:

    P = (2 St/D) × F × E × T

    P = Design pressure in pounds per square inch (kPa) gauge.

    S = Yield strength in pounds per square inch (kPa) determined in accordance with § 192.107.

    D = Nominal outside diameter of the pipe in inches (millimeters).

    t = Nominal wall thickness of the pipe in inches (millimeters). If this is unknown, it is determined in accordance with § 192.109. Additional wall thickness required for concurrent external loads in accordance with § 192.103 may not be included in computing design pressure.

    F = Design factor determined in accordance with § 192.111.

    E = Longitudinal joint factor determined in accordance with § 192.113.

    T = Temperature derating factor determined in accordance with § 192.115.

    (b) If steel pipe that has been subjected to cold expansion to meet the SMYS is subsequently heated, other than by welding or stress relieving as a part of welding, the design pressure is limited to 75 percent of the pressure determined under paragraph (a) of this section if the temperature of the pipe exceeds 900 °F (482 °C) at any time or is held above 600 °F (316 °C) for more than 1 hour.

    [35 FR 13257, Aug. 19, 1970, as amended by Amdt. 192-47, 49 FR 7569, Mar. 1, 1984; Amdt. 192-85, 63 FR 37502, July 13, 1998]