Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 10 - Energy |
Chapter I - Nuclear Regulatory Commission |
Part 20 - Standards for Protection Against Radiation |
Appendix A to Part 20 - Assigned Protection Factors for Respirators a
Latest version.
-
Appendix A to Part 20 - Assigned Protection Factors for Respiratorsa
Operating mode Assigned
Protection
FactorsI. Air Purifying Respirators [Particulateb only]c: Filtering facepiece disposabled Negative Pressure (d) Facepiece, halfe Negative Pressure 10 Facepiece, full Negative Pressure 100 Facepiece, half Powered air-purifying respirators 50 Facepiece, full Powered air-purifying respirators 1000 Helmet/hood Powered air-purifying respirators 1000 Facepiece, loose-fitting Powered air-purifying respirators 25 II. Atmosphere supplying respirators [particulate, gases and vaporsf]: 1. Air-line respirator: Facepiece, half Demand 10 Facepiece, half Continuous Flow 50 Facepiece, half Pressure Demand 50 Facepiece, full Demand 100 Facepiece, full Continuous Flow 1000 Facepiece, full Pressure Demand 1000 Helmet/hood Continuous Flow 1000 Facepiece, loose-fitting Continuous Flow 25 Suit Continuous Flow (g) 2. Self-contained breathing Apparatus (SCBA): Facepiece, full Demand h 100 Facepiece, full Pressure Demand i 10,000 Facepiece, full Demand, Recirculating h 100 Facepiece, full Positive Pressure Recirculating i 10,000 III. Combination Respirators: Any combination of air-purifying and atmosphere-supplying respirators Assigned protection factor for type and mode of operation as listed above. [64 FR 54558, Oct. 7, 1999; 64 FR 55524, Oct. 13, 1999]