Appendix A to Part 20 - Assigned Protection Factors for Respirators a  


Latest version.
  • Appendix A to Part 20 - Assigned Protection Factors for Respiratorsa

    Operating mode Assigned
    Protection
    Factors
    I. Air Purifying Respirators [Particulateb only]c:
    Filtering facepiece disposabled Negative Pressure (d)
    Facepiece, halfe Negative Pressure 10
    Facepiece, full Negative Pressure 100
    Facepiece, half Powered air-purifying respirators 50
    Facepiece, full Powered air-purifying respirators 1000
    Helmet/hood Powered air-purifying respirators 1000
    Facepiece, loose-fitting Powered air-purifying respirators 25
    II. Atmosphere supplying respirators [particulate, gases and vaporsf]:
    1. Air-line respirator:
    Facepiece, half Demand 10
    Facepiece, half Continuous Flow 50
    Facepiece, half Pressure Demand 50
    Facepiece, full Demand 100
    Facepiece, full Continuous Flow 1000
    Facepiece, full Pressure Demand 1000
    Helmet/hood Continuous Flow 1000
    Facepiece, loose-fitting Continuous Flow 25
    Suit Continuous Flow (g)
    2. Self-contained breathing Apparatus (SCBA):
    Facepiece, full Demand h 100
    Facepiece, full Pressure Demand i 10,000
    Facepiece, full Demand, Recirculating h 100
    Facepiece, full Positive Pressure Recirculating i 10,000
    III. Combination Respirators:
    Any combination of air-purifying and atmosphere-supplying respirators Assigned protection factor for type and mode of operation as listed above.

    [64 FR 54558, Oct. 7, 1999; 64 FR 55524, Oct. 13, 1999]