§ 431.371 - Submission of data.  


Latest version.
  • (a) Certification. (1) Except as provided in paragraph (a)(2) of this section, each manufacturer or private labeler before distributing into the stream of commerce any basic model of covered equipment covered by this subpart and subject to an energy or water conservation standard set forth in this part, shall certify by means of a compliance statement and a certification report that each basic model meets the applicable energy or water conservation standard. Except as provided in paragraph (a)(2) of this section, each manufacturer or private labeler shall file a compliance statement and its first certification report with the Department on or before (180 days after the Department of Energy publishes a document in the Federal Register announcing OMB approval of the information collection requirements in § 431.371). The compliance statement, signed by the company official submitting the statement, and the certification report(s) shall be sent by certified mail to: U.S. Department of Energy, Building Technologies Program, Mailstop EE-2J, 1000 Independence Avenue, SW., Washington, DC 20585-0121, or e-mailed to the Department at: certification.report@ee.doe.gov.

    (2) Each manufacturer or private labeler of a basic model of commercial clothes washer, distribution transformer, traffic signal module, pedestrian module, and commercial prerinse spray valve shall file a compliance statement and its first certification report with the Department on or before (180 days after the Department of Energy publishes a document in the Federal Register announcing OMB approval of the information collection requirements in § 431.371).

    (3) Amendment of information. If information in a compliance statement or certification report previously submitted to the Department under this section is found to be incorrect, each manufacturer or private labeler (or an authorized representative) must submit the corrected information to the Department at the address and in the manner described in this section.

    (4) Notices designating a change of third-party representative must be sent to the Department at the address and in the manner described in this section.

    (5) The compliance statement, which each manufacturer or private labeler need not submit more than once unless the information on the report changes, shall include all information specified in the format set forth in appendix A of this subpart and shall certify, with respect to each basic model currently produced by the manufacturer and new basic models it introduces in the future, that:

    (i) Each basic model complies and will comply with the applicable energy or water conservation standard;

    (ii) All representations as to efficiency in the manufacturer's certification report(s) are and will be based on testing and/or use of an AEDM in accordance with 10 CFR Part 431;

    (iii) All information reported in the certification report(s) is and will be true, accurate, and complete; and

    (iv) The manufacturer or private labeler is aware of the penalties associated with violations of the Act, the regulations thereunder, and 18 U.S.C. 1001, which prohibits knowingly making false statements to the Federal Government.

    (6) Each manufacturer must submit to the Department a certification report for all of its basic models.

    (i) For covered equipment that are subject to standards other than distribution transformers and electric motors, the certification report (for which a suggested format is set forth in appendix B of this subpart) shall include for each basic model the product type, product class, manufacturer's name, private labeler's name(s) (if applicable), and the manufacturer's model number(s), and:

    (A) The thermal efficiency as a percentage and the maximum rated capacity (rated maximum input) in Btu/h of commercial warm air furnaces;

    (B) The combustion efficiency as a percentage and the capacity (rated maximum input) in Btu/h of commercial package boilers;

    (C) The seasonal energy efficiency ratio and the cooling capacity in Btu/h of small commercial, air cooled, three-phase, packaged air conditioners less than 65,000 Btu/h;

    (D) The energy efficiency ratio and the cooling capacity in Btu/h of small commercial water-cooled and evaporatively cooled packaged air conditioners less than 65,000 Btu/h;

    (E) The energy efficiency ratio and the cooling capacity in Btu/h of large and very large commercial air cooled, water-cooled, and evaporatively cooled packaged air conditioners;

    (F) The energy efficiency ratio and the cooling capacity in Btu/h of packaged terminal air conditioners;

    (G) The seasonal energy efficiency ratio, the heating seasonal performance factor and the cooling capacity in Btu/h of small commercial air cooled, three-phase packaged air conditioning heat pumps less than 65,000 Btu/h;

    (H) The energy efficiency ratio, the coefficient of performance and the cooling capacity in Btu/h of small commercial water-source packaged air conditioning heat pumps;

    (I) The energy efficiency ratio, the coefficient of performance and the cooling capacity in Btu/h of large and very large air cooled commercial package air conditioning heat pumps;

    (J) The energy efficiency ratio, coefficient of performance and the cooling capacity in Btu/h of packaged terminal heat pumps;

    (K) The maximum standby loss in percent per hour of electric storage water heaters;

    (L) The minimum thermal efficiency in percent, the maximum standby loss in Btu/h, and the size (input capacity) in Btu/h of gas- and oil-fired storage water heaters;

    (M) The minimum thermal efficiency in percent, maximum standby loss in Btu/h, and the size (storage capacity) in gallons of gas- and oil-fired instantaneous water heaters and gas- and oil-fired hot water supply boilers greater than or equal to 10 gallons;

    (N) The minimum thermal efficiency in percent and the size (storage capacity) in gallons of gas- and oil-fired instantaneous water heaters and gas- and oil-fired hot water supply boilers less than 10 gallons;

    (O) The minimum thermal insulation and the storage capacity of unfired hot water storage tanks;

    (P) The maximum daily energy consumption in kilowatt hours per day and volume in cubic feet of refrigerators with solid doors, refrigerators with transparent doors, freezers with solid doors, and freezers with transparent doors;

    (Q) The maximum daily energy consumption in kilowatt hours per day and adjusted volume in cubic feet of refrigerator-freezers with solid doors;

    (R) The equipment type, type of cooling, maximum energy use in kilowatt hours per 100 pounds of ice, maximum condenser water use in gallons per 100 pounds of ice, and harvest rate in pounds of ice per 24 hours of commercial ice makers;

    (S) The modified energy factor and water consumption factor of commercial clothes washers;

    (T) The input power demand in watts of illuminated exit signs;

    (U) The nominal and maximum wattage in watts and signal type of traffic signal modules and pedestrian modules; and

    (V) The flow rate in gallons per minute of commercial prerinse spray valves.

    (ii) For the least efficient basic model of distribution transformer within each “kilovolt ampere (kVA) grouping” for which this part prescribes an efficiency standard, the certification report (for which a suggested format is set forth in appendix C of this subpart shall include the kVA rating, the insulation type (i.e., low-voltage dry-type, medium-voltage dry-type or liquid-immersed), the number of phases (i.e., single-phase or three-phase), the basic impulse insulation level (BIL) group rating (for medium-voltage dry-types), the model number(s), the efficiency, and the method used to determine the efficiency (i.e., actual testing or an AEDM). As used in this section, a “kVA grouping” is a group of basic models which all have the same kVA rating, have the same insulation type (i.e., low-voltage dry-type, medium-voltage dry-type or liquid-immersed), have the same number of phases (i.e., single-phase or three-phase), and, for medium-voltage dry-types, have the same BIL group rating (i.e., 20-45 kV BIL, 46-95 kV BIL or greater than 96 kV BIL).

    (7) Copies of reports to the Federal Trade Commission that include the information specified in paragraph (a)(6) of this section could serve in lieu of the certification report.

    (b) Model Modifications. Any change to a basic model that affects energy or water consumption (in the case of prerinse spray valves) constitutes the addition of a new basic model. If such a change reduces consumption, the new model shall be considered in compliance with the standard without any additional testing. If, however, such a change increases consumption while meeting the standard, then

    (1) For distribution transformers, the manufacturer must submit all information required by paragraph (a)(6)(ii) of this section for the new basic model, unless the manufacturer has previously submitted to the Department a certification report for a basic model of distribution transformer that is in the same kVA grouping as the new basic model, and that has a lower efficiency than the new basic model;

    (2) For other equipment, the manufacturer must submit all information required by paragraph (a)(6) of this section for the new basic model; and

    (3) Any such submission shall be by certified mail, to: Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, Forrestal Building, 1000 Independence Avenue, SW., Washington, DC 20585-0121, or e-mailed to the Department at: certification.report@ee.doe.gov.

    (c) Discontinued model. For equipment other than distribution transformers, when production of a basic model has ceased and is no longer being distributed, the manufacturer shall report this, by certified mail, to: U.S. Department of Energy, Building Technologies Program, Mailstop EE-2J, 1000 Independence Avenue, SW., Washington, DC 20585-0121, or e-mailed to the Department at: certification.report@ee.doe.gov. For each basic model, the report shall include: equipment type, equipment class, the manufacturer's name, the private labeler's name(s), if applicable, and the manufacturer's model number. If the reporting of discontinued models coincides with the submittal of a certification report, such information can be included in the certification report.

    (d) Third-party representation. A manufacturer or private labeler may elect to use a third party (such as a trade association or other authorized representative) to submit the certification report to the Department. Such certification reports shall include all the information specified in paragraph (a)(6) of this section. Third parties submitting certification reports shall include the names of the manufacturers or private labelers who authorized the submittal of the certification reports to the Department on their behalf. The third-party representative also may submit discontinued model information on behalf of an authorizing manufacturer.