§ 25.899 - Electrical bonding and protection against static electricity.


Latest version.
  • § 25.899 Electrical bonding and protection against static electricity.

    (a) Electrical bonding and protection against static electricity must be designed to minimize accumulation of electrostatic charge that would cause -

    (1) Human injury from electrical shock,

    (2) Ignition of flammable vapors, or

    (3) Interference with installed electrical/electronic equipment.

    (b) Compliance with paragraph (a) of this section may be shown by -

    (1) Bonding the components properly to the airframe; or

    (2) Incorporating other acceptable means to dissipate the static charge so as not to endanger the airplane, personnel, or operation of the installed electrical/electronic systems.

    [Amdt. 25-123, 72 FR 63405, Nov. 8, 2007]