§ 3280.111 Toilet compartments.
have(a) Each toilet compartment must
widthbe a minimum
, with a minimum clear space of 21 inchesof 30 inches
A toilet located adjacent to a wall must have the center-line of the toilet located a minimum of 15 inches from the wall. A toilet located adjacent to a tub must have the center-line of the toilet located a minimum of 12 inches from the outside edge of the tub. [78 FR 73981, Dec. 9, 2013wide, except, when the toilet is located adjacent to the short dimension of the tub, the distance from the tub, to the center line of the toilet must not be less than 12 inches. At least 21 inches of clear space must be provided in front of each toilet.
(b) All bathroom passage doors in single-section homes must have a minimum clear opening width of 23 inches, and bathroom passage doors in multi-section homes must have a minimum clear opening width of 27 inches.
[86 FR 2517, Jan. 12, 2021]