§ 250.451 - What must I do in certain situations involving BOP equipment or systems?  


Latest version.
  • Link to an amendment published at 81 FR 26020, April 29, 2016.

    The table in this section describes actions that lessees must take when certain situations occur with BOP systems during drilling activities.

    If you encounter the following situation:Then you must .  .  .
    (a) BOP equipment does not hold the required pressure during a test,Correct the problem and retest the affected equipment.
    (b) Need to repair or replace a surface or subsea BOP system,First place the well in a safe, controlled condition (e.g., before drilling out a casing shoe or after setting a cement plug, bridge plug, or a packer).
    (c) Need to postpone a BOP test due to well-control problems such as lost circulation, formation fluid influx, or stuck drill pipe,Record the reason for postponing the test in the driller's report and conduct the required BOP test on the first trip out of the hole.
    (d) BOP control station or pod that does not function properly,Suspend further drilling operations until that station or pod is operable.
    (e) Want to drill with a tapered drill-string,Install two or more sets of conventional or variable-bore pipe rams in the BOP stack to provide for the following: two sets of rams must be capable of sealing around the larger-size drill string and one set of pipe rams must be capable of sealing around the smaller-size drill string.
    (f) Install casing rams in a BOP stack,Test the ram bonnets before running casing.
    (g) Want to use an annular BOP with a rated working pressure less than the anticipated surface pressure,Demonstrate that your well control procedures or the anticipated well conditions will not place demands above its rated working pressure and obtain approval from the District Manager.
    (h) Use a subsea BOP system in an ice-scour area,Install the BOP stack in a well cellar. The well cellar must be deep enough to ensure that the top of the stack is below the deepest probable ice-scour depth.
    (i) You activate blind-shear rams or casing shear rams during a well control situation, in which pipe or casing is sheared,Retrieve, physically inspect, and conduct a full pressure test of the BOP stack after the situation is fully controlled.
    (j) Need to remove the BOP stackHave a minimum of two barriers in place prior to BOP removal. The BSEE District Manager may require additional barriers.

    [76 FR 64462, Oct. 18, 2011, as amended at 77 FR 50894, Aug. 22, 2012]