§ 57.6161 - Auxiliary facilities.


Latest version.
  • § 57.6161 Auxiliary facilities.

    (a) Auxiliary facilities used to store explosive material near work places shall be wooden, box-type containers equipped with covers or doors, or facilities constructed or mined-out to provide equivalent impact resistance and confinement.

    (b) The auxiliary facilities shall be -

    (1) Constructed of nonsparking material on the inside when used for the storage of explosives;

    (2) Kept clean, suitably dry, and orderly;

    (3) Kept in repair;

    (4) Located out of the line of blasts so they will not be subjected to damaging shock or flyrock;

    (5) Identified with warning signs or coded to indicate the contents with markings visible from any approach;

    (6) Located at least 15 feet from all haulageways and electrical equipment, or placed entirely within a mined-out recess in the rib used exclusively for explosive material;

    (7) Filled with no more than a one-week supply of explosive material;

    (8) Separated by at least 25 feet from other facilities used to store detonators; and

    (9) Kept securely locked unless all access to the mine is either locked or attended.