Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 30 - Mineral Resources |
Chapter I - Mine Safety and Health Administration, Department of Labor |
SubChapter K - Metal and Nonmetal Mine Safety and Health |
Part 57 - Safety and Health Standards - Underground Metal and Nonmetal Mines |
Subpart E - Explosives |
Electric Blasting - Surface and Underground |
§ 57.6407 - Circuit testing.
-
§ 57.6407 Circuit testing.
A blasting galvanometer or other instrument designed for testing blasting circuits shall be used to test the following:
(a) In surface operations -
(1) Continuity of each electric detonator in the blasthole prior to stemming and connection to the blasting line;
(2) Resistance of individual series or the resistance of multiple balanced series to be connected in parallel prior to their connection to the blasting line;
(3) Continuity of blasting lines prior to the connection of electric or electronic detonator series; and
(4) Total blasting circuit resistance prior to connection to the power source.
(b) In underground operations -
(1) Continuity of each electric detonator series; and
(2) Continuity of blasting lines prior to the connection of electric or electronic detonators.
[61 FR 36801, July 12, 1996, as amended at 85 FR 2027, Jan. 14, 2020]