Code of Federal Regulations (Last Updated: July 5, 2024) |
![]() |
Title 30 - Mineral Resources |
![]() |
Chapter I - Mine Safety and Health Administration, Department of Labor |
![]() |
SubChapter O - Coal Mine Safety and Health |
![]() |
Part 77 - Mandatory Safety Standards, Surface Coal Mines and Surface Work Areas of Underground Coal Mines |
![]() |
Subpart C - Surface Installations |
§ 77.213 - Draw-off tunnel escapeways.
Latest version.
-
§ 77.213 Draw-off tunnel escapeways.
When it is necessary for a tunnel to be closed at one end, an escapeway not less than 30 inches in diameter (or of the equivalent, if the escapeway does not have a circular cross section) shall be installed which extends from the closed end of the tunnel to a safe location on the surface; and, if the escapeway is inclined more than 30 degrees from the horizontal it shall be equipped with a ladder which runs the full length of the inclined portion of the escapeway.