Table 3 to Subpart AAAA of Part 60 - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)  


Latest version.
  • Table 3 to Subpart AAAA of Part 60 - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    For the following continuous emission monitoring systems Use the following methods in appendix A of this part to validate pollutant concentration levels Use the following methods in appendix A of this part to measure oxygen (or carbon dioxide)
    1. Nitrogen Oxides (Class I units only)a Method 7, 7A, 7B, 7C, 7D, or 7E Method 3 or 3A.
    2. Sulfur Dioxide Method 6 or 6C Method 3 or 3A.
    3. Carbon Monoxide Method 10, 10A, or 10B Method 3 or 3A.