Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 40 - Protection of Environment |
Chapter I - Environmental Protection Agency |
SubChapter C - Air Programs |
Part 60 - Standards of Performance for New Stationary Sources |
Subpart BBBB - Emission Guidelines and Compliance Times for Small Municipal Waste Combustion Units Constructed on or Before August 30, 1999 |
Table 7 to Subpart BBBB of Part 60 - Model Rule - Requirements for Continuous Emission Monitoring Systems (CEMS)
Latest version.
-
Table 7 to Subpart BBBB of Part 60 - Model Rule - Requirements for Continuous Emission Monitoring Systems (CEMS)
For the following pollutants Use the following span values for CEMS Use the following performance specifications in appendix B of this part for your CEMS If needed to meet minimum data requirements, use the following alternate methods in appendix A of this part to collect data 1. Opacity 100 percent opacity P.S. 1 Method 9. 2. Nitrogen Oxides (Class I units only) Control device outlet: 125 percent of the maximum expected hourly potential nitrogen oxides emissions of the municipal waste combustion unit P.S. 2 Method 7E. 3. Sulfur Dioxide Inlet to control device: 125 percent of the maximum expected hourly potential sulfur dioxide emissions of the municipal waste combustion unit P.S. 2 Method 6C. Control device outlet: 50 percent of the maximum expected hourly potential sulfur dioxide emissions of the municipal waste combustion unit 4. Carbon Monoxide 125 percent of the maximum expected hourly potential carbon monoxide emissions of the municipal waste combustion unit P.S. 4A Method 10 with alternative interference trap. 5. Oxygen or Carbon Dioxide 25 percent oxygen or 25 percent carbon dioxide P.S. 3 Method 3A or 3B.