Table 2 to Subpart DDDD of Part 60 - Model Rule - Emission Limitations That Apply to Incinerators Before [Date To Be Specified in State Plan]  


Latest version.
  • Table 2 to Subpart DDDD of Part 60 - Model Rule - Emission Limitations That Apply to Incinerators Before [Date To Be Specified in State Plan]1

    For the air pollutant You must meet this
    emission limitation2
    Using this averaging time3 And determining compliance using this method3
    Cadmium 0.004 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part).
    Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B, of appendix A of this part).
    Dioxins/furans (toxic equivalency basis) 0.41 nanograms per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 23 of appendix A of this part).
    Hydrogen chloride 62 parts per million by dry volume 3-run average (For Method 26, collect a minimum volume of 120 liters per run. For Method 26A, collect a minimum volume of 1 dry standard cubic meter per run) Performance test (Method 26 or 26A at 40 CFR part 60, appendix A-8).
    Lead 0.04 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part).
    Mercury 0.47 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 or 30B at 40 CFR part 60, appendix A-8) or ASTM D6784-02 (Reapproved 2008).4
    Opacity 10 percent Three 1-hour blocks consisting of ten 6-minute average opacity values Performance test (Method 9 at 40 CFR part 60, appendix A-4).
    Nitrogen oxides 388 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Methods 7 or 7E at 40 CFR part 60, appendix A-4).
    Particulate matter 70 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 5 or 29 of appendix A of this part).
    Sulfur dioxide 20 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 6 or 6c of appendix A of this part).