Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 40 - Protection of Environment |
Chapter I - Environmental Protection Agency |
SubChapter C - Air Programs |
Part 60 - Standards of Performance for New Stationary Sources |
Subpart DDDD - Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units |
Table 9 to Subpart DDDD of Part 60 - Model Rule - Emission Limitations That Apply to Small, Remote Incinerators After May 20, 2011 [Date To Be Specified in State Plan] 1
Latest version.
-
Table 9 to Subpart DDDD of Part 60 - Model Rule - Emission Limitations That Apply to Small, Remote Incinerators After May 20, 2011 [Date To Be Specified in State Plan]1
For the air pollutant You must meet this
emission limitation2Using this averaging time3 And determining compliance using this method3 Cadmium 0.95 milligrams per dry standard cubic meter 3-run average (collect a minimum volume of 1 dry standard cubic meters per run) Performance test (Method 29 at 40 CFR part 60, appendix A-8). Carbon monoxide 64 parts per million dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10 at 40 CFR part 60, appendix A-4). Dioxins/furans (total mass basis) 4,400 nanograms per dry standard cubic meter 3-run average (collect a minimum volume of 1 dry standard cubic meters per run) Performance test (Method 23 at 40 CFR part 60, appendix A-7). Dioxins/furans (toxic equivalency basis) 180 nanograms per dry standard cubic meter 3-run average (collect a minimum volume of 1 dry standard cubic meters) Performance test (Method 23 at 40 CFR part 60, appendix A-7). Fugitive ash Visible emissions for no more than 5 percent of the hourly observation period Three 1-hour observation periods Visible emissions test (Method 22 at 40 CFR part 60, appendix A-7). Hydrogen chloride 300 parts per million dry volume 3-run average (For Method 26, collect a minimum volume of 120 liters per run. For Method 26A, collect a minimum volume of 1 dry standard cubic meter per run) Performance test (Method 26 or 26A at 40 CFR part 60, appendix A-8). Lead 2.1 milligrams per dry standard cubic meter 3-run average (collect a minimum volume of 1 dry standard cubic meters) Performance test (Method 29 at 40 CFR part 60, appendix A-8). Use ICPMS for the analytical finish. Mercury 0.0053 milligrams per dry standard cubic meter 3-run average (For Method 29 and ASTM D6784-02 (Reapproved 2008),3 collect a minimum volume of 2 dry standard cubic meters per run. For Method 30B, collect a minimum sample as specified in Method 30B at 40 CFR part 60, appendix A) Performance test (Method 29 or 30B at 40 CFR part 60, appendix A-8) or ASTM D6784-02 (Reapproved 2008).4 Nitrogen oxides 190 parts per million dry volume 3-run average (for Method 7E, 1 hour minimum sample time per run) Performance test (Method 7 or 7E at 40 CFR part 60, appendix A-4). Particulate matter (filterable) 270 milligrams per dry standard cubic meter 3-run average (collect a minimum volume of 1 dry standard cubic meters) Performance test (Method 5 or 29 at 40 CFR part 60, appendix A-3 or appendix A-8). Sulfur dioxide 150 parts per million dry volume 3-run average (for Method 6, collect a minimum of 20 liters per run; for Method 6C, 1 hour minimum sample time per run) Performance test (Method 6 or 6c at 40 CFR part 60, appendix A-4).