Table 3 to Subpart MMMM of Part 60 - Model Rule - Emission Limits and Standards for Existing Multiple Hearth Sewage Sludge Incineration Units  


Latest version.
  • Table 3 to Subpart MMMM of Part 60 - Model Rule - Emission Limits and Standards for Existing Multiple Hearth Sewage Sludge Incineration Units

    For the air pollutant You must meet this emission limita Using these averaging methods and
    minimum sampling volumes or durations
    And determining compliance using this
    method
    Particulate matter 80 milligrams per dry standard cubic meter 3-run average (collect a minimum volume of 0.75 dry standard cubic meters per run) Performance test (Method 5 at 40 CFR part 60, appendix A-3; Method 26A or Method 29 at 40 CFR part 60, appendix A-8).
    Hydrogen chloride 1.2 parts per million by dry volume 3-run average (For Method 26, collect a minimum volume of 200 liters per run. For Method 26A, collect a minimum volume of 1 dry standard cubic meters per run) Performance test (Method 26 or 26A at 40 CFR part 60, appendix A-8).
    Carbon monoxide 3,800 parts per million by dry volume 3-run average (collect sample for a minimum duration of one hour per run) Performance test (Method 10, 10A, or 10B at 40 CFR part 60, appendix A-4).
    Dioxins/furans (total mass basis) 5.0 nanograms per dry standard cubic meter; or 3-run average (collect a minimum volume of 1 dry standard cubic meters per run) Performance test (Method 23 at 40 CFR part 60, appendix A-7).
    Dioxins/furans (toxic equivalency basis)b 0.32 nanograms per dry standard cubic meter
    Mercury 0.28 milligrams per dry standard cubic meter 3-run average (For Method 29 and ASTM D6784-02 (Reapproved 2008),c collect a minimum volume of 1 dry standard cubic meters per run. For Method 30B, collect a minimum sample as specified in Method 30B at 40 CFR part 60, appendix A-8) Performance test (Method 29 at 40 CFR part 60, appendix A-8; Method 30B at 40 CFR part 60, appendix A-8; or ASTM D6784-02 (Reapproved 2008)).c
    Oxides of nitrogen 220 parts per million by dry volume 3-run average (Collect sample for a minimum duration of one hour per run) Performance test (Method 7 or 7E at 40 CFR part 60, appendix A-4).
    Sulfur dioxide 26 parts per million by dry volume 3-run average (For Method 6, collect a minimum volume of 200 liters per run. For Method 6C, collect sample for a minimum duration of one hour per run) Performance test (Method 6 or 6C at 40 CFR part 40, appendix A-4; or ANSI/ASME PTC 19.10-1981).c
    Cadmium 0.095 milligrams per dry standard cubic meter 3-run average (collect a minimum volume of 1 dry standard cubic meters per run) Performance test (Method 29 at 40 CFR part 60, appendix A-8).
    Lead 0.30 milligrams per dry standard cubic meter 3-run average (collect a minimum volume of 1 dry standard cubic meters per run) Performance test (Method 29 at 40 CFR part 60, appendix A-8).
    Fugitive emissions from ash handling Visible emissions of combustion ash from an ash conveying system (including conveyor transfer points) for no more than 5 percent of the hourly observation period Three 1-hour observation periods Visible emission test (Method 22 of appendix A-7 of this part).