Table 3 to Subpart NNNa of Part 60 - —Operating Parameters, Operating Parameter Limits and Data Monitoring, Recordkeeping and Compliance Frequencies  


Latest version.
  • Table 3 to Subpart NNNa of Part 60—Operating Parameters, Operating Parameter Limits and Data Monitoring, Recordkeeping and Compliance Frequencies

    For the
    operating
    parameter
    applicable to
    you, as
    specified
    in table 2
    You must
    establish
    the following
    operating
    parameter
    limit . . .
    And you must monitor, record, and demonstrate continuous
    compliance using these minimum frequencies . . .
    Data measurement Data
    recording
    Data
    averaging
    period for compliance
    Absorbers
    1. Exit temperature of the absorbing liquid Maximum temperature Continuous Every 15 minutes 3-hour block average.
    2. Exit specific gravity Exit specific gravity range Continuous Every 15 minutes 3-hour block average.
    Boilers or process heaters
    (with a design heat input capacity <44MW and vent stream is not introduced with or as the primary fuel)
    3. Firebox temperature Minimum firebox temperature Continuous Every 15 minutes 3-hour block average.
    Catalytic incinerators
    4. Temperature in gas stream immediately before the catalyst bed Minimum temperature Continuous Every 15 minutes 3-hour block average.
    5. Temperature difference between the catalyst bed inlet and the catalyst bed outlet Minimum temperature difference Continuous Every 15 minutes 3-hour block average.
    Carbon adsorbers
    6. Total regeneration stream mass flow during carbon bed regeneration cycle(s) Minimum mass flow during carbon bed regeneration cycle(s) Continuously during regeneration Every 15 minutes during regeneration cycle Total flow for each regeneration cycle.
    7. Total regeneration stream volumetric flow during carbon bed regeneration cycle(s) Minimum volumetric flow during carbon bed regeneration cycle(s) Continuously during regeneration Every 15 minutes during regeneration cycle Total flow for each regeneration cycle.
    8. Temperature of the carbon bed after regeneration [and within 15 minutes of completing any cooling cycle(s)] Maximum temperature of the carbon bed after regeneration Continuously during regeneration and for 15 minutes after completing any cooling cycle(s) Every 15 minutes during regeneration cycle (including any cooling cycle) Average of regeneration cycle.
    9. Breakthrough As defined in § 60.661a As required by § 60.663a(a)(6)(iii)(B) Each monitoring event N/A.
    Condensers
    10. Exit (product side) temperature Maximum temperature Continuous Every 15 minutes 3-hour block average.
    Scrubbers for halogenated vent streams
    11. pH of scrubber effluent Minimum pH Continuous Every 15 minutes 3-hour block average.
    12. Influent liquid flow Minimum inlet liquid flow Continuous Every 15 minutes 3-hour block average.
    13. Influent liquid flow rate and gas stream flow rate Minimum influent liquid-to-gas ratio Continuous Every 15 minutes 3-hour block average.
    Thermal incinerators
    14. Firebox temperature Minimum firebox temperature Continuous Every 15 minutes 3-hour block average.
    Control devices other than an incinerator, boiler, process heater, or flare; or recovery devices other than an absorber, condenser, or carbon adsorber
    15. As specified by the Administrator 15. As specified by the Administrator 15. As specified by the Administrator 15. As specified by the Administrator 15. As specified by the Administrator.