Table 2 to Subpart OOO of Part 60 - Stack Emission Limits for Affected Facilities With Capture Systems  


Latest version.
  • Table 2 to Subpart OOO of Part 60 - Stack Emission Limits for Affected Facilities With Capture Systems

    For * * * The owner or operator must meet a PM limit of * * * And the owner or operator must meet an opacity limit of * * * The owner or operator must demonstrate compliance with these limits by conducting * * *
    Affected facilities (as defined in §§ 60.670 and 60.671) that commenced construction, modification, or reconstruction after August 31, 1983 but before April 22, 2008 0.05 g/dscm (0.022 gr/dscf)a 7 percent for dry control devicesb An initial performance test according to § 60.8 of this part and § 60.675 of this subpart; and
    Monitoring of wet scrubber parameters according to § 60.674(a) and § 60.676(c), (d), and (e).
    Affected facilities (as defined in §§ 60.670 and 60.671) that commence construction, modification, or reconstruction on or after April 22, 2008 0.032 g/dscm (0.014 gr/dscf)a Not applicable (except for individual enclosed storage bins)
    7 percent for dry control devices on individual enclosed storage bins
    An initial performance test according to § 60.8 of this part and § 60.675 of this subpart; and
    Monitoring of wet scrubber parameters according to § 60.674(a) and § 60.676(c), (d), and (e); and
    Monitoring of baghouses according to § 60.674(c), (d), or (e) and § 60.676(b).