Code of Federal Regulations (Last Updated: October 10, 2024) |
Title 40 - Protection of Environment |
Chapter I—Environmental Protection Agency |
SubChapter C—Air Programs |
Part 60 - Standards of Performance for New Stationary Sources |
Table 2 to Subpart RRRa of Part 60 - —Monitoring Requirements for Complying With 98 Weight-Percent Reduction of Total Organic Compounds Emissions or a Limit of 20 Parts Per Million by Volume
Latest version.
-
Table 2 to Subpart RRRa of Part 60—Monitoring Requirements for Complying With 98 Weight-Percent Reduction of Total Organic Compounds Emissions or a Limit of 20 Parts Per Million by Volume
Non-flare control device or recovery device Parameters to be monitored 1. All control and recovery devices a. Presence of flow diverted to the atmosphere from the control and recovery device; or
b. Monthly inspections of sealed valves2. Absorber a. Exit temperature of the absorbing liquid; and
b. Exit specific gravity3. Boiler or process heater with a design heat input capacity less than 44 megawatts and vent stream is not introduced with or as the primary fuel Firebox temperaturea 4. Catalytic incinerator Temperature upstream and downstream of the catalyst bed 5. Carbon adsorber, regenerative a. Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s); and
b. Temperature of the carbon bed after regeneration [and within 15 minutes of completing any cooling cycle(s)]6. Carbon adsorber, non-regenerative or regenerated offsite Breakthrough 7. Condenser Exit (product side) temperature 8. Scrubber for halogenated vent streams a. pH of scrubber effluent;and
b. Scrubber liquid and gas flow rates9. Thermal incinerator Firebox temperaturea 10. Control devices other than an incinerator, boiler, process heater, or flare; or recovery devices other than an absorber, condenser, or carbon adsorber As specified by the Administrator