Table 2 to Subpart DDDD of Part 63 - Operating Requirements
If you operate a(n) . . . You must . . . Or you must . . . (1) Thermal oxidizer Maintain the 3-hour block average firebox temperature above the minimum temperature established during the performance test Maintain the 3-hour block average THC concentration1 in the thermal oxidizer exhaust below the maximum concentration established during the performance test. (2) Catalytic oxidizer Maintain the 3-hour block average catalytic oxidizer temperature above the minimum temperature established during the performance test; AND check the activity level of a representative sample of the catalyst annually except as specified in footnote “2” to this table Maintain the 3-hour block average THC concentration1 in the catalytic oxidizer exhaust below the maximum concentration established during the performance test. (3) Biofilter Maintain the 24-hour block biofilter bed temperature within the range established according to § 63.2262(m) Maintain the 24-hour block average THC concentration1 in the biofilter exhaust below the maximum concentration established during the performance test. (4) Control device other than a thermal oxidizer, catalytic oxidizer, or biofilter Petition the EPA Administrator for site-specific operating parameter(s) to be established during the performance test and maintain the average operating parameter(s) within the range(s) established during the performance test Maintain the 3-hour block average THC concentration1 in the control device exhaust below the maximum concentration established during the performance test. (5) Process unit that meets a compliance option in Table 1A to this subpart, or a process unit that generates debits in an emissions average without the use of a control device Maintain on a daily basis the process unit controlling operating parameter(s) within the ranges established during the performance test according to § 63.2262(n) Maintain the 3-hour block average THC concentration1 in the process unit exhaust below the maximum concentration established during the performance test. [85 FR 49460, Aug. 13, 2020]