Table 12 to Subpart DDDDD of Part 63 - Alternative Emission Limits for New or Reconstructed Boilers and Process Heaters That Commenced Construction or Reconstruction After May 20, 2011, and Before December 23, 2011  


Latest version.
  • Table 12 to Subpart DDDDD of Part 63 - Alternative Emission Limits for New or Reconstructed Boilers and Process Heaters That Commenced Construction or Reconstruction After May 20, 2011, and Before December 23, 2011

    If your boiler or process heater is in this subcategory . . . For the following pollutants . . . The emissions must not exceed the following emission limits, except during periods of startup and shutdown . . . Using this specified sampling volume or test run duration . . .
    1. Units in all subcategories designed to burn solid fuel a. HCl 0.022 lb per MMBtu of heat input For M26A, collect a minimum of 1 dscm per run; for M26 collect a minimum of 120 liters per run.
    b. Mercury 3.5E-06a lb per MMBtu of heat input For M29, collect a minimum of 3 dscm per run; for M30A or M30B, collect a minimum sample as specified in the method; for ASTM D6784b collect a minimum of 3 dscm.
    2. Units design to burn coal/solid fossil fuel a. Filterable PM (or TSM) 1.1E-03 lb per MMBtu of heat input; or (2.3E-05 lb per MMBtu of heat input) Collect a minimum of 3 dscm per run.
    3. Pulverized coal boilers designed to burn coal/solid fossil fuel a. Carbon monoxide (CO) (or CEMS) 130 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average; or (320 ppm by volume on a dry basis corrected to 3 percent oxygen,c 30-day rolling average) 1 hr minimum sampling time.
    4. Stokers designed to burn coal/solid fossil fuel a. CO (or CEMS) 130 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average; or (340 ppm by volume on a dry basis corrected to 3 percent oxygen,c 10-day rolling average) 1 hr minimum sampling time.
    5. Fluidized bed units designed to burn coal/solid fossil fuel a. CO (or CEMS) 130 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average; or (230 ppm by volume on a dry basis corrected to 3 percent oxygen,c 30-day rolling average) 1 hr minimum sampling time.
    6. Fluidized bed units with an integrated heat exchanger designed to burn coal/solid fossil fuel a. CO (or CEMS) 140 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average; or (150 ppm by volume on a dry basis corrected to 3 percent oxygen,c 30-day rolling average) 1 hr minimum sampling time.
    7. Stokers/sloped grate/others designed to burn wet biomass fuel a. CO (or CEMS) 620 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average; or (390 ppm by volume on a dry basis corrected to 3 percent oxygen,c 30-day rolling average) 1 hr minimum sampling time.
    b. Filterable PM (or TSM) 3.0E-02 lb per MMBtu of heat input; or (2.6E-05 lb per MMBtu of heat input) Collect a minimum of 2 dscm per run.
    8. Stokers/sloped grate/others designed to burn kiln-dried biomass fuel a. CO
    b. Filterable PM (or TSM)
    460 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average
    3.0E-02 lb per MMBtu of heat input; or (4.0E-03 lb per MMBtu of heat input)
    1 hr minimum sampling time.
    Collect a minimum of 2 dscm per run.
    9. Fluidized bed units designed to burn biomass/bio-based solids a. CO (or CEMS) 260 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average; or (310 ppm by volume on a dry basis corrected to 3 percent oxygen,c 30-day rolling average) 1 hr minimum sampling time.
    b. Filterable PM (or TSM) 9.8E-03 lb per MMBtu of heat input; or (8.3E-05a lb per MMBtu of heat input) Collect a minimum of 3 dscm per run.
    10. Suspension burners designed to burn biomass/bio-based solids a. CO (or CEMS) 2,400 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average; or (2,000 ppm by volume on a dry basis corrected to 3 percent oxygen,c 10-day rolling average) 1 hr minimum sampling time.
    b. Filterable PM (or TSM) 3.0E-02 lb per MMBtu of heat input; or (6.5E-03 lb per MMBtu of heat input) Collect a minimum of 2 dscm per run.
    11. Dutch Ovens/Pile burners designed to burn biomass/bio-based solids a. CO (or CEMS) 470 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average; or (520 ppm by volume on a dry basis corrected to 3 percent oxygen,c 10-day rolling average) 1 hr minimum sampling time.
    b. Filterable PM (or TSM) 3.2E-03 lb per MMBtu of heat input; or (3.9E-05 lb per MMBtu of heat input) Collect a minimum of 3 dscm per run.
    12. Fuel cell units designed to burn biomass/bio-based solids a. CO
    b. Filterable PM (or TSM)
    910 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average
    2.0E-02 lb per MMBtu of heat input; or (2.9E-05 lb per MMBtu of heat input)
    1 hr minimum sampling time.
    Collect a minimum of 2 dscm per run.
    13. Hybrid suspension grate boiler designed to burn biomass/bio-based solids a. CO (or CEMS) 1,500 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average; or (900 ppm by volume on a dry basis corrected to 3 percent oxygen,c 30-day rolling average) 1 hr minimum sampling time.
    b. Filterable PM (or TSM) 2.6E-02 lb per MMBtu of heat input; or (4.4E-04 lb per MMBtu of heat input) Collect a minimum of 3 dscm per run.
    14. Units designed to burn liquid fuel a. HCl 4.4E-04 lb per MMBtu of heat input For M26A: Collect a minimum of 2 dscm per run; for M26, collect a minimum of 240 liters per run.
    b. Mercury 4.8E-07a lb per MMBtu of heat input For M29, collect a minimum of 4 dscm per run; for M30A or M30B, collect a minimum sample as specified in the method; for ASTM D6784b collect a minimum of 4 dscm.
    15. Units designed to burn heavy liquid fuel a. CO 130 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average 1 hr minimum sampling time.
    b. Filterable PM (or TSM) 1.3E-02 lb per MMBtu of heat input; or (7.5E-05 lb per MMBtu of heat input) Collect a minimum of 2 dscm per run.
    16. Units designed to burn light liquid fuel a. CO 130 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average 1 hr minimum sampling time.
    b. Filterable PM (or TSM) 1.3E-03a lb per MMBtu of heat input; or (2.9E-05 lb per MMBtu of heat input) Collect a minimum of 3 dscm per run.
    17. Units designed to burn liquid fuel that are non-continental units a. CO 130 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average based on stack test 1 hr minimum sampling time.
    b. Filterable PM (or TSM) 2.3E-02 lb per MMBtu of heat input; or (8.6E-04 lb per MMBtu of heat input) Collect a minimum of 4 dscm per run.
    18. Units designed to burn gas 2 (other) gases a. CO 130 ppm by volume on a dry basis corrected to 3 percent oxygen, 3-run average 1 hr minimum sampling time.
    b. HCl 1.7E-03 lb per MMBtu of heat input For M26A, Collect a minimum of 2 dscm per run; for M26, collect a minimum of 240 liters per run.
    c. Mercury 7.9E-06 lb per MMBtu of heat input For M29, collect a minimum of 3 dscm per run; for M30A or M30B, collect a minimum sample as specified in the method; for ASTM D6784b collect a minimum of 3 dscm.
    d. Filterable PM (or TSM) 6.7E-03 lb per MMBtu of heat input; or (2.1E-04 lb per MMBtu of heat input) Collect a minimum of 3 dscm per run.

    [80 FR 72834, Nov. 20, 2015]