Table 3 to Subpart FFFF of Part 63 - Emission Limits for Hydrogen Halide and Halogen HAP Emissions or HAP Metals Emissions From Process Vents  


Latest version.
  • Table 3 to Subpart FFFF of Part 63 - Emission Limits for Hydrogen Halide and Halogen HAP Emissions or HAP Metals Emissions From Process Vents

    As required in § 63.2465, you must meet each emission limit in the following table that applies to your process vents that contain hydrogen halide and halogen HAP emissions or PM HAP emissions:

    For each . . . You must . . .
    1. Process with uncontrolled hydrogen halide and halogen HAP emissions from process vents ≥1,000 lb/yr a. Reduce collective hydrogen halide and halogen HAP emissions by ≥99 percent by weight or to an outlet concentration ≤20 ppmv by venting through one or more closed-vent systems to any combination of control devices, or
    b. Reduce the halogen atom mass emission rate from the sum of all batch process vents and each individual continuous process vent to ≤0.45 kg/hr by venting through one or more closed-vent systems to a halogen reduction device.
    2. Process at a new source with uncontrolled emissions from process vents ≥150 lb/yr of HAP metals Reduce overall emissions of HAP metals by ≥97 percent by weight.

    [68 FR 63888, Nov. 10, 2003, as amended at 71 FR 40340, July 14, 2006]