Table 13 to Subpart G of Part 63 - —Wastewater—Monitoring Requirements for Control Devices  


Latest version.
  • Table 13 to Subpart G of Part 63—Wastewater—Monitoring Requirements for Control Devices

    Control Device

    Table 13 to Subpart G of Part 63—Wastewater—Monitoring Requirements for Control Devices

    Control device Monitoring equipment required Parameters to be monitored Frequency
    All control devices1. Flow indicator installed at all bypass lines to the atmosphere and equipped with continuous recorderb or 1. Presence of flow diverted from the control device to the atmosphere or Hourly records of whether the flow indicator was operating and whether a diversion was detected at any time during each hour.
    2. Valves sealed closed with car-seal or lock-and-key configuration2. Monthly inspections of sealed valvesMonthly.
    Thermal IncineratorTemperature monitoring device installed in firebox or in ductwork immediately downstream of fireboxa and equipped with a continuous recorderb Firebox temperatureContinuous.
    Catalytic IncineratorTemperature monitoring device installed in gas stream immediately before and after catalyst bed and equipped with a continuous recorderb 1. Temperature upstream of catalyst bed or
    2. Temperature difference across catalyst bed
    Continuous.
    Flare (if meeting the requirements of § 63.139(c)(3))Heat sensing device installed at the pilot light and equipped with a continuous recordera Presence of a flame at the pilot lightHourly records of whether the monitor was continuously operating and whether the pilot flame was continuously present during each hour.
    Flare (if meeting the requirements of § 63.108)The monitoring equipment is specified in § 63.108The parameters are specified in § 63.108The frequency is specified in § 63.108.
    Boiler or process heater <44 megawatts and vent stream is not mixed with the primary fuelTemperature monitoring device installed in fireboxa and equipped with continuous recorderb Combustion temperatureContinuous.
    CondenserTemperature monitoring device installed at condenser exit and equipped with continuous recorderb Condenser exit (product side) temperatureContinuous.
    Carbon adsorber (regenerative, regenerated onsite)Integrating regeneration stream flow monitoring device having an accuracy of ±10 percent, and Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s)For each regeneration cycle, record the total regeneration stream mass or volumetric flow.
    Carbon bed temperature monitoring deviceTemperature of carbon bed after regeneration [and within 15 minutes of completing any cooling cycle(s)]For each regeneration cycle and within 15 minutes of completing any cooling cycle, record the carbon bed temperature.
    Carbon adsorber (Non-regenerative or regenerative, regenerated offsite)Organic compound concentration monitoring device.c Organic compound concentration of adsorber exhaustDaily or at intervals no greater than 20 percent of the design carbon replacement interval, whichever is greater.
    The monitoring equipment is specified in § 63.139(d)(5)The parameters are specified in § 63.139(d)(5)The frequency is specified in § 63.139(d)(5).
    Organic monitoring deviced Organic monitoring device installed at the outlet of the control deviceOrganic compound concentration of control device exhaustContinuous.
    Alternative monitoring parametersOther parameters may be monitored upon approval from the Administrator in accordance with the requirements in § 63.143(e)(3)

    [89 FR 43218, May 16, 2024]