Table 1 to Subpart HHHH of Part 63 - Minimum Requirements for Monitoring and Recordkeeping  


Latest version.
  • Table 1 to Subpart HHHH of Part 63 - Minimum Requirements for Monitoring and Recordkeeping

    As stated in § 63.2998(c), you must comply with the minimum requirements for monitoring and recordkeeping in the following table:

    You must monitor these parameters: At this frequency: And record for the monitored parameter:
    1. Thermal oxidizer temperature14 Continuously 15-minute and 3-hour block averages.
    2. Other process or control device parameters specified in your OMM plan24 As specified in your OMM plan As specified in your OMM plan.
    3. Urea-formaldehyde resin solids application rate4 On each operating day, calculate the average lb/h application rate for each product manufactured during that day The average lb/h value for each product manufactured during the day.
    4. Resin free-formaldehyde content4 For each lot of resin purchased The value for each lot used during the operating day.
    5. Loss-on-ignition34 Measured at least once per day, for each product manufactured during that day The value for each product manufactured during the operating day.
    6. UF-to-latex ratio in the binder34 For each batch of binder prepared the operating day The value for each batch of binder prepared during the operating day.
    7. Weight of the final mat product per square (lb/roofing square)34 Each product manufactured during the operating day The value for each product manufactured during the operating day.
    8. Average nonwoven wet-formed fiberglass mat production rate (roofing square/h)34 For each product manufactured during the operating day The average value for each product manufactured during operating day.

    [84 FR 6697, Feb. 28, 2019]