Table 4 to Subpart MMMMM of Part 63 - Initial Compliance With Emission Limits  


Latest version.
  • Table 4 to Subpart MMMMM of Part 63 - Initial Compliance With Emission Limits

    As stated in § 63.8806, you must comply with the requirements to demonstrate initial compliance with the applicable emission limits in the following table:

    For . . . For the following emission limit . . . You have demonstrated initial compliance if . . .
    1. Each new, reconstructed, or existing loop slitter adhesive use affected source Eliminate use of HAP-based adhesives You do not use HAP-based adhesives.
    2. Each new or reconstructed flame lamination affected source using a scrubber Reduce HAP emissions by 90 percent The average HAP emissions, measured over the period of the performance test(s), are reduced by 90 percent.
    3. Each new or reconstructed flame lamination affected source using any other control device emissions by Reduce HAP emissions by 90 percent The average HAP emissions, measured over the period of the performance test(s), are reduced by 90 percent.
    4. Each existing flame lamination affected source Emit no more than 1.45 pounds per hour of HCl per flame lamination line The average HCl emissions, measured over the period of the performance test(s) do not exceed 1.45 pounds per hour per flame lamination line.

    [68 FR 18070, Apr. 14, 2003, as amended at 86 FR 64403, Nov. 18, 2021]