Table 2 to Subpart O of Part 63 - —Standards for ARVs  


Latest version.
  • Table 2 to Subpart O of Part 63—Standards for ARVs

    As required in § 63.362(d), for each ARV, you must meet the applicable standard in the following table:

    For each . . . For which . . . You must . . . You must comply with the standard . . .
    1. Existing ARV a. Facility EtO use is at least 10 tpy i. Continuously reduce EtO emissions by 99 percent1 Until April 6, 2026.
    b. Facility EtO use is at least 30 tpy i. Continuously reduce EtO emissions by 99.9 percent 2 3 No later than April 6, 2026.
    c. Facility EtO use is at least 10 tpy but less than 30 tpy i. Continuously reduce EtO emissions by 99.6 percent 2 3 No later than April 6, 2026.
    d. Facility EtO use is less than 10 tpy i. Continuously reduce EtO emissions by 99 percent 2 4 No later than April 5, 2027.
    2. New ARV a. Initial startup is on or before April 5, 2024, and facility EtO use is at least 10 tpy i. Continuously reduce EtO emissions by 99.9 percent 2 5 No later than April 5, 2024.
    b. Initial startup is on or before April 5, 2024, and facility EtO use is less than 10 tpy i. Continuously reduce EtO emissions by 99 percent 2 6 No later than April 5, 2024.
    c. Initial startup is after April 5, 2024, and facility EtO use is at least 10 tpy i. Continuously reduce EtO emissions by 99.9 percent 2 5 Upon startup of the source.
    d. Initial startup is after April 5, 2024, and facility EtO use is less than 10 tpy i. Continuously reduce EtO emissions by 99 percent 2 6 Upon startup of the source.