Table 4 to Subpart OOO of Part 63 - Operating Parameter Levels  


Latest version.
  • Table 4 to Subpart OOO of Part 63 - Operating Parameter Levels

    Device Parameters to be monitored Established operating
    parameter(s)
    Scrubber pH of scrubber effluent; and scrubber liquid and gas flow rates Minimum pH; and minimum liquid/gas ratio
    Absorber Exit temperature of the absorbing liquid; and exit specific gravity of the absorbing liquid Maximum temperature; and maximum specific gravity
    Condenser Exit temperature Maximum temperature
    Carbon absorber Total regeneration steam or nitrogen flow, or pressure (gauge or absolute)a during carbon bed regeneration cycle; and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) Maximum flow or pressure; and maximum temperature
    Thermal incinerator Firebox temperature Minimum temperature
    Catalytic incinerator Temperature upstream and downstream of the catalyst bed Minimum upstream temperature; and minimum temperature difference across the catalyst bed
    Boiler or process heater Firebox temperature Minimum temperature
    Other devices (or as an alternate to the requirements previously presented in this table)b Organic HAP concentration level or reading at outlet of device Maximum organic HAP concentration or reading