Table 28 to Subpart UUU of Part 63 - Continuous Compliance With Operating Limits for Inorganic HAP Emissions From Catalytic Reforming Units  


Latest version.
  • Table 28 to Subpart UUU of Part 63 - Continuous Compliance With Operating Limits for Inorganic HAP Emissions From Catalytic Reforming Units

    As stated in § 63.1567(c)(1), you shall meet each requirement in the following table that applies to you.

    For each new and existing catalytic reforming unit using this type of control device or system . . . For this operating limit . . . You shall demonstrate continuous compliance during coke burn-off and catalyst rejuvenation by . . .
    1. Wet scrubber a. The daily average pH or alkalinity of the water (or scrubbing liquid) exiting the scrubber must not fall below the level established during the performance test Collecting the hourly and daily average pH or alkalinity monitoring data according to § 63.15721; and maintaining the daily average pH or alkalinity above the operating limit established during the performance test.
    b. The daily average liquid-to-gas ratio must not fall below the level established during the performance test Collecting the hourly average gas flow rate2 and total water (or scrubbing liquid) flow rate monitoring data according to § 63.1572; and determining and recording the hourly average liquid-to-gas ratio; and determining and recording the daily average liquid-to-gas ratio; and maintaining the daily average liquid-to-gas ratio above the limit established during the performance test.
    2. Internal scrubbing system or no control device (e.g., hot regen system) meeting HCl concentration limit The daily average HCl concentration in the catalyst regenerator exhaust gas must not exceed the limit established during the performance test Measuring and recording the HCl concentration at least 4 times during a regeneration cycle (equally spaced in time) or every 4 hours, whichever is more frequent, using a colormetric tube sampling system; calculating the daily average HCl concentration as an arithmetic average of all samples collected in each 24-hour period from the start of the coke burn-off cycle or for the entire duration of the coke burn-off cycle if the coke burn-off cycle is less than 24 hours; and maintaining the daily average HCl concentration below the applicable operating limit.
    3. Internal scrubbing system meeting percent HCl reduction standard a. The daily average pH or alkalinity of the water (or scrubbing liquid) exiting the internal scrubbing system must not fall below the limit established during the performance test Collecting the hourly and daily average pH or alkalinity monitoring data according to § 63.15721 and maintaining the daily average pH or alkalinity above the operating limit established during the performance test.
    b. The daily average liquid-to-gas ratio must not fall below the level established during the performance test Collecting the hourly average gas flow rate2 and total water (or scrubbing liquid) flow rate monitoring data according to § 63.1572; and determining and recording the hourly average liquid-to-gas ratio; and determining and recording the daily average liquid-to-gas ratio; and maintaining the daily average liquid-to-gas ratio above the limit established during the performance test.
    4. Fixed-bed gas-solid adsorption systems a. The daily average temperature of the gas entering or exiting the adsorption system must not exceed the limit established during the performance test Collecting the hourly and daily average temperature monitoring data according to § 63.1572; and maintaining the daily average temperature below the operating limit established during the performance test.
    b. The HCl concentration in the exhaust gas from the fixed-bed gas-solid adsorption system must not exceed the limit established during the performance test Measuring and recording the concentration of HCl weekly or during each regeneration cycle, whichever is less frequent, using a colormetric tube sampling system at a point within the adsorbent bed not to exceed 90 percent of the total length of the adsorption bed during coke-burn-off and catalyst rejuvenation; implementing procedures in the operating and maintenance plan if the HCl concentration at the sampling location within the adsorption bed exceeds the operating limit; and maintaining the HCl concentration in the gas from the adsorption system below the applicable operating limit.
    5. Moving-bed gas-solid adsorption system (e.g., ChlorsorbTM System) a. The daily average temperature of the gas entering or exiting the adsorption system must not exceed the limit established during the performance test Collecting the hourly and daily average temperature monitoring data according to § 63.1572; and maintaining the daily average temperature below the operating limit established during the performance test.
    b. The weekly average chloride level on the sorbent entering the adsorption system must not exceed the design or manufacturer's recommended limit (1.35 weight percent for the ChlorsorbTM System) Collecting samples of the sorbent exiting the adsorption system three times per week (on non-consecutive days); and analyzing the samples for total chloride3; and determining and recording the weekly average chloride concentration; and maintaining the chloride concentration below the design or manufacturer's recommended limit (1.35 weight percent for the ChlorsorbTM System).
    c. The weekly average chloride level on the sorbent exiting the adsorption system must not exceed the design or manufacturer's recommended limit (1.8 weight percent for the ChlorsorbTM System) Collecting samples of the sorbent exiting the adsorption system three times per week (on non-consecutive days); and analyzing the samples for total chloride concentration; and determining and recording the weekly average chloride concentration; and maintaining the chloride concentration below the design or manufacturer's recommended limit (1.8 weight percent ChlorsorbTM System).

    [70 FR 6954, Feb. 9, 2005, as amended at 80 FR 75308, Dec. 1, 2015]