Table W-6 of Subpart W of Part 98 - Default Methane Emission Factors for LNG Import and Export Equipment  


Latest version.
  • Link to an amendment published at 81 FR 86518, November 30, 2016.

    LNG import and export equipmentEmission factor (scf/hour/
    component)
    Leaker Emission Factors—LNG Terminals Components, LNG Service
    Valve1.19
    Pump Seal4.00
    Connector0.34
    Other11.77
    Population Emission Factors—LNG Terminals Compressor, Gas Service
    Vapor Recovery Compressor24.17

    1“Other” equipment type should be applied for any equipment type other than connectors, pumps, or valves.

    2Emission Factors is in units of “scf/hour/compressor.”

    [76 FR 80594, Dec. 23, 2011]