Table W-7 to Subpart W of Part 98 - —Default Methane Emission Factors for Natural Gas Distribution  


Latest version.
  • Table W-7 to Subpart W of Part 98 - Default Methane Emission Factors for Natural Gas Distribution

    Natural gas distribution Emission factor (scf/hour/
    component)
    Leaker Emission Factors - Transmission-Distribution Transfer Station1 Components, Gas Service
    Connector 1.69
    Block Valve 0.557
    Control Valve 9.34
    Pressure Relief Valve 0.27
    Orifice Meter 0.212
    Regulator 0.772
    Open-ended Line 26.131
    Population Emission Factors - Below Grade Metering-Regulating station1 Components, Gas Service2
    Below Grade M&R Station, Inlet Pressure >300 psig 1.30 Below Grade M&R Station, Inlet Pressure 100 to 300 psig 0.20
    Below Grade M&R Station, Inlet Pressure <100 psig 0.10
    Population Emission Factors - Distribution Mains, Gas Service3
    Unprotected Steel 12.58
    Protected Steel 0.35
    Plastic 1.13
    Cast Iron 27.25
    Population Emission Factors - Distribution Services, Gas Service4
    Unprotected Steel 0.19
    Protected Steel 0.02
    Plastic 0.001
    Copper 0.03

    [76 FR 80594, Dec. 23, 2011]