§ 1065.205 - Performance specifications for measurement instruments.  


Latest version.
  • § 1065.205 Performance specifications for measurement instruments.

    Your test system as a whole must meet all the calibrations, verifications, and test-validation criteria specified outside elsewhere in this section part for laboratory testing or field testing, as applicable. We recommend that your instruments meet the specifications in Table 1 of this section for all ranges you use for testing. We also recommend that you keep any documentation you receive from instrument manufacturers showing that your instruments meet the specifications in Table 1 of this section.

    Table 1 of § 1065.205 - Recommended Performance Specifications for Measurement Instruments

    Measurement instrument Measured quantity symbol Complete system rise time (t10-90) and fall time (t90-10)a Recording update frequency Accuracyb Repeatabilityb Noiseb Engine speed transducer fn 1 s1 Hz means2% of pt. or 0.5% of max1% of pt. or 0.25% of max0.05% of max. Engine torque transducer T 1 s1 Hz means2% of pt. or 1% of max1% of pt. or 0.5% of max0.05% of max. Electrical work (active-power meter) W 1 s1 Hz means2% of pt. or 0.5% of max1% of pt. or 0.25% of max0.05% of max. General pressure transducer (not a part of another instrument) p 5 s1 Hz2% of pt. or 1% of max1% of pt. or 0.5% of max0.1% of max. Atmospheric pressure meter for PM-stabilization and balance environments patmos 50 s5 times per hour50 Pa25 Pa5 Pa General purpose atmospheric pressure meter patmos 50 s5 times per hour250 Pa100Pa50 Pa Temperature sensor for PM-stabilization and balance environments T 50 s0.1 Hz0.25 K0.1 K0.1 K Other temperature sensor (not a part of another instrument) T 10 s0.5 Hz0.4% of pt. K or 0.2% of max K0.2% of pt. K or 0.1% of max K0.1% of max. Dewpoint sensor for intake air, PM-stabilization and balance environments Tdew 50 s0.1 Hz0.25 K0.1 K0.02 K Other dewpoint sensor Tdew 50 s0.1 Hz1 K0.5 K0.1 K Fuel flow meterc (Fuel totalizer) 5 s ( - )1 Hz ( - )2% of pt. or 1.5% of max1% of pt. or 0.75% of max0.5% of max. Total diluted exhaust meter (CVS)c (With heat exchanger before meter) 1 s (5 s)1 Hz means (1 Hz)2% of pt. or 1.5% of max1% of pt. or 0.75% of max1% of max. Dilution air, inlet air, exhaust, and sample flow metersc 1 s1 Hz means of 5 Hz samples2.5% of pt. or 1.5% of max1.25% of pt. or 0.75% of max1% of max. Continuous gas analyzer x 5 s1 Hz2% of pt. or 2% of meas1% of pt. or 1% of meas1% of max. Batch gas analyzer x 2% of pt. or 2% of meas1% of pt. or 1% of meas1% of max. Gravimetric PM balance mPM See § 1065.7900.5 µg Inertial PM balance mPM 5 s1 Hz2% of pt. or 2% of meas1% of pt. or 1% of meas0.2% of max [79 FR 23759, Apr. 28, 2014

    the following table:

    [86 FR 34534, June 29, 2021]