Code of Federal Regulations (Last Updated: October 10, 2024) |
Title 40 - Protection of Environment |
Chapter I - Environmental Protection Agency |
SubChapter D - Water Programs |
Part 141 - National Primary Drinking Water Regulations |
Subpart Y - Revised Total Coliform Rule |
§ 141.852 - Analytical methods and laboratory certification.
-
§ 141.852 Analytical methods and laboratory certification.
(a) Analytical methodology.
(1) The standard sample volume required for analysis, regardless of analytical method used, is 100 ml.
(2) Systems need only determine the presence or absence of total coliforms and E. coli; a determination of density is not required.
(3) The time from sample collection to initiation of test medium incubation may not exceed 30 hours. Systems are encouraged but not required to hold samples below 10 deg. C during transit.
(4) If water having residual chlorine (measured as free, combined, or total chlorine) is to be analyzed, sufficient sodium thiosulfate (Na2S2O3) must be added to the sample bottle before sterilization to neutralize any residual chlorine in the water sample. Dechlorination procedures are addressed in Section 9060A.2 of Standard Methods for the Examination of Water and Wastewater (20th and 21st editions).
(5) Systems must conduct total coliform and E. coli analyses in accordance with one of the analytical methods in the following table or one of the alternative methods listed in Appendix A to subpart C of part 141.
Organism Methodology category Method1 Citation1 Total Coliforms Lactose Fermentation Methods Standard Total Coliform Fermentation Technique Standard Methods 9221 B.1, B.2 (20th ed.; 21st ed.).2 3 Standard Methods Online 9221 B.1, B.2-99.2 3 Presence-Absence (P-A) Coliform Test Standard Methods 9221 D.1, D.2 (20th ed.; 21st ed.).2 7 Standard Methods Online 9221 D.1, D.2-99.2 7 Membrane Filtration Methods Standard Total Coliform Membrane Filter Procedure Standard Methods 9222 B, C (20th ed.; 21st ed.).2 4 Standard Methods Online 9222 B-972 4, 9222 C-97.2 4 Membrane Filtration using MI medium EPA Method 1604.2 m-ColiBlue24® Test2 4 Chromocult2 4 Enzyme Substrate Methods Colilert® Standard Methods 9223 B (20th ed.; 21st ed.).2 5 Standard Methods Online 9223 B-97.2 5 Colisure® Standard Methods 9223 B (20th ed.; 21st ed.).2 5 6 Standard Methods Online 9223 B-97.2 5 6 E*Colite® Test2 Readycult® Test2 modified Colitag® Test2 Escherichia coli Escherichia coli Procedure (following Lactose Fermentation Methods) EC-MUG medium Standard Methods 9221 F.1 (20th ed.; 21st ed.)2 Escherichia coli Partition Method EC broth with MUG (EC-MUG) Standard Methods 9222 G.1c(2) (20th ed.; 21st ed.)2 8 NA-MUG medium Standard Methods 9222 G.1c(1) (20th ed.; 21st ed.)2 Membrane Filtration Methods Membrane Filtration using MI medium
m-ColiBlue24® Test2 4EPA Method 16042 Chromocult2 4 Enzyme Substrate Methods Colilert® Standard Methods 9223 B (20th ed.; 21st ed.)2 5 Standard Methods Online 9223 B-972 5 6 Colisure® Standard Methods 9223 B (20th ed.; 21st ed.)2 5 6 Standard Methods Online
9223 B-972 5 6E*Colite® Test2 Readycult® Test2 modified Colitag® Test2 (b) Laboratory certification. Systems must have all compliance samples required under this subpart analyzed by a laboratory certified by the EPA or a primacy State to analyze drinking water samples. The laboratory used by the system must be certified for each method (and associated contaminant(s)) used for compliance monitoring analyses under this rule.
(c) Incorporation by reference. The standards required in this section are incorporated by reference into this section with the approval of the Director of the Federal Register under 5 U.S.C. 552(a) and 1 CFR part 51. To enforce any edition other than that specified in this section, EPA must publish notice of change in the Federal Register and the material must be available to the public. All approved material is available for inspection either electronically at www.regulations.gov, in hard copy at the Water Docket, or from the sources indicated below. The Docket ID is EPA-HQ-OW-2008-0878. Hard copies of these documents may be viewed at the Water Docket in the EPA Docket Center, (EPA/DC) EPA West, Room 3334, 1301 Constitution Ave. NW., Washington, DC. The EPA Docket Center Public Reading Room is open from 8:30 a.m. to 4:30 p.m., Monday through Friday, excluding legal holidays. The telephone number for the Public Reading Room is 1-202-566-1744, and the telephone number for the Water Docket is 1-202-566-2426. Copyrighted materials are only available for viewing in hard copy. These documents are also available for inspection at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 1-202-741-6030 or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
(1) American Public Health Association, 800 I Street, NW., Washington, DC 20001.
(i) “Standard Methods for the Examination of Water and Wastewater,” 20th edition (1998):
(A) Standard Methods 9221, “Multiple-Tube Fermentation Technique for Members of the Coliform Group,” B.1, B.2, “Standard Total Coliform Fermentation Technique.”
(B) Standard Methods 9221, “Multiple-Tube Fermentation Technique for Members of the Coliform Group,” D.1, D.2, “Presence-Absence (P-A) Coliform Test.”
(C) Standard Methods 9222, “Membrane Filter Technique for Members of the Coliform Group,” B, “Standard Total Coliform Membrane Filter Procedure.”
(D) Standard Methods 9222, “Membrane Filter Technique for Members of the Coliform Group,” C, “Delayed-Incubation Total Coliform Procedure.”
(E) Standard Methods 9223, “Enzyme Substrate Coliform Test,” B, “Enzyme Substrate Test,” Colilert® and Colisure®.
(F) Standard Methods 9221, “Multiple Tube Fermentation Technique for Members of the Coliform Group,” F.1, “Escherichia coli Procedure: EC-MUG medium.”
(G) Standard Methods 9222, “Membrane Filter Technique for Members of the Coliform Group,” G.1.c(2), “Escherichia coli Partition Method: EC broth with MUG (EC-MUG).”
(H) Standard Methods 9222, “Membrane Filter Technique for Members of the Coliform Group,” G.1.c(1), “Escherichia coli Partition Method: NA-MUG medium.”
(ii) “Standard Methods for the Examination of Water and Wastewater,” 21st edition (2005):
(A) Standard Methods 9221, “Multiple-Tube Fermentation Technique for Members of the Coliform Group,” B.1, B.2, “Standard Total Coliform Fermentation Technique.”
(B) Standard Methods 9221, “Multiple-Tube Fermentation Technique for Members of the Coliform Group,” D.1, D.2, “Presence-Absence (P-A) Coliform Test.”
(C) Standard Methods 9222, “Membrane Filter Technique for Members of the Coliform Group,” B, “Standard Total Coliform Membrane Filter Procedure.”
(D) Standard Methods 9222, “Membrane Filter Technique for Members of the Coliform Group,” C, “Delayed-Incubation Total Coliform Procedure.”
(E) Standard Methods 9223, “Enzyme Substrate Coliform Test,” B, “Enzyme Substrate Test,” Colilert® and Colisure®.
(F) Standard Methods 9221, “Multiple Tube Fermentation Technique for Members of the Coliform Group,” F.1, “Escherichia coli Procedure: EC-MUG medium.”
(G) Standard Methods 9222, “Membrane Filter Technique for Members of the Coliform Group,” G.1.c(2), “Escherichia coli Partition Method: EC broth with MUG (EC-MUG).”
(H) Standard Methods 9222, “Membrane Filter Technique for Members of the Coliform Group,” G.1.c(1), “Escherichia coli Partition Method: NA-MUG medium.”
(iii) “Standard Methods Online” available at http://www.standardmethods.org:
(A) Standard Methods Online 9221, “Multiple-Tube Fermentation Technique for Members of the Coliform Group” (1999), B.1, B.2-99, “Standard Total Coliform Fermentation Technique.”
(B) Standard Methods Online 9221, “Multiple-Tube Fermentation Technique for Members of the Coliform Group” (1999), D.1, D.2-99, “Presence-Absence (P-A) Coliform Test.”
(C) Standard Methods Online 9222, “Membrane Filter Technique for Members of the Coliform Group” (1997), B-97, “Standard Total Coliform Membrane Filter Procedure.”
(D) Standard Methods Online 9222, “Membrane Filter Technique for Members of the Coliform Group” (1997), C-97, “Delayed-Incubation Total Coliform Procedure.”
(E) Standard Methods Online 9223, “Enzyme Substrate Coliform Test” (1997), B-97, “Enzyme Substrate Test”, Colilert® and Colisure®.
(2) Charm Sciences, Inc., 659 Andover Street, Lawrence, MA 01843-1032, telephone 1-800-343-2170:
(i) E*Colite® - “Charm E*ColiteTM Presence/Absence Test for Detection and Identification of Coliform Bacteria and Escherichia coli in Drinking Water,” January 9, 1998.
(ii) [Reserved]
(3) CPI International, Inc., 5580 Skylane Blvd., Santa Rosa, CA, 95403, telephone 1-800-878-7654:
(i) modified Colitag®, ATP D05-0035 - “Modified ColitagTM Test Method for the Simultaneous Detection of E. coli and other Total Coliforms in Water,” August 28, 2009.
(ii) [Reserved]
(4) EMD Millipore (a division of Merck KGaA, Darmstadt Germany), 290 Concord Road, Billerica, MA 01821, telephone 1-800-645-5476:
(i) Chromocult - “Chromocult® Coliform Agar Presence/Absence Membrane Filter Test Method for Detection and Identification of Coliform Bacteria and Escherichia coli for Finished Waters,” November 2000, Version 1.0.
(ii) Readycult® - “Readycult® Coliforms 100 Presence/Absence Test for Detection and Identification of Coliform Bacteria and Escherichia coli in Finished Waters,” January 2007, Version 1.1.
(5) EPA's Water Resource Center (MC-4100T), 1200 Pennsylvania Avenue NW., Washington, DC 20460, telephone 1-202-566-1729:
(i) EPA Method 1604, EPA 821-R-02-024 - “EPA Method 1604: Total Coliforms and Escherichia coli in Water by Membrane Filtration Using a Simultaneous Detection Technique (MI Medium),” September 2002, http://www.epa.gov/nerlcwww/1604sp02.pdf.
(ii) [Reserved]
(6) Hach Company, P.O. Box 389, Loveland, CO 80539, telephone 1-800-604-3493:
(i) m-ColiBlue24® - “Membrane Filtration Method m-ColiBlue24® Broth,” Revision 2, August 17, 1999.
(ii) [Reserved]
[78 FR 10354, Feb. 13, 2013, as amended at 79 FR 10669, Feb. 26, 2014]