§ 419.56 - Standards of performance for new sources (NSPS).  


Latest version.
  • § 419.56 Standards of performance for new sources (NSPS).

    (a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):

    Pollutant or pollutant property NSPS effluent limitation
    Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed
    Metric units (kilograms per 1,000 m3 of feedstock)
    BOD5 41.622.1
    TSS28.117.9
    COD1 295.0152.0
    Oil and grease12.66.7
    Phenolic compounds0.300.14
    Ammonia as N23.410.7
    Sulfide0.260.12
    Total chromium0.640.37
    Hexavalent chromium0.0520.024
    pH(2)(2)
    English units (pounds per 1,000 bbl of feedstock)
    BOD5 14.77.8
    TSS9.96.3
    COD1 104.054.0
    Oil and grease4.52.4
    Phenolic compounds0.1050.051
    Ammonia as N8.33.8
    Sulfide0.0930.042
    Total chromium0.2200.13
    Hexavalent chromium0.0190.0084
    pH(2)(2)

    (b) The limits set forth in paragraph (a) of this section are to be multiplied by the following factors to calculate the maximum for any one day and maximum average of daily values for thirty consecutive days.

    (1) Size factor.

    1,000 bbl of feedstock per stream day Size factor
    Less than 124.90.73
    125.0 to 149.90.76
    150.0 to 174.90.83
    175.0 to 199.90.91
    200 to 224.90.99
    225 or greater1.04

    (2) Process factor.

    Process configuration Process factor
    Less than 6.490.75
    6.5 to 7.490.82
    7.5 to 7.990.92
    8.0 to 8.491.00
    8.5 to 8.991.10
    9.0 to 9.491.20
    9.5 to 9.991.30
    10.0 to 10.491.42
    10.5 to 10.991.54
    11.0 to 11.491.68
    11.5 to 11.991.83
    12.0 to 12.491.99
    12.5 to 12.992.17
    13.0 or greater2.26

    (3) See the comprehensive example in subpart D, § 419.42(b)(3).

    (c) The provisions of § 419.16(c) apply to discharges of process wastewater pollutants attributable to ballast water by a point source subject to the provision of this subpart.

    (d) The quantity and quality of pollutants or pollutant properties controlled by this paragraph, attributable to once-through cooling water, are excluded from the discharge allowed by paragraph (b) of this section. Once-through cooling water may be discharged with a total organic carbon concentration not to exceed 5 mg/l.

    (e) Effluent Limitations limitations for Runoffrunoff. [Reserved]

    [47 FR 46446, Oct. 18, 1982, as amended at 50 FR 28523, 28528, July 12, 1985; 50 FR 32414, Aug. 12, 1985]