§ 430.36 - Pretreatment standards for existing sources (PSES).  


Latest version.
  • § 430.36 Pretreatment standards for existing sources (PSES).

    Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart that introduces pollutants into a publicly owned treatment works must: comply with 40 CFR part 403; and achieve the following pretreatment standards for existing sources (PSES) if it uses chlorophenolic-containing biocides. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using those biocides. PSES must be attained on or before July 1, 1984:

    Subpart C

    [PSES for unbleached kraft facilities]

    Pollutant or pollutant property Maximum for any 1 day
    Milligrams/liter Kg/kkg (or pounds per 1,000 lb) of producta
    Pentachlorophenol (0.011)(12.6)/y 0.00058
    Trichlorophenol (0.010)(12.6)/y 0.00053
    y = wastewater discharged in kgal per ton of product.

    Subpart C

    [PSES for unbleached kraft facilities where pulp and paper are produced using the unbleached kraft-neutral sulfite semi-chemical (cross recovery) process and/or a combined unbleached kraft and semi-chemical process, wherein the spent semi-chemical cooking liquor is burned within the unbleached kraft chemical recovery system]

    Pollutant or pollutant property Maximum for any 1 day
    Milligrams/liter Kg/kkg (or pounds per 1,000 lb) of producta
    Pentachlorophenol (0.011)(14.0)/y 0.00064
    Trichlorophenol (0.010)(14.0)/y 0.00059
    y = wastewater discharged in kgal per ton of product.