§ 435.44 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).  


Latest version.
  • § 435.44 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

    Except as provided in 40 CFR 125.30-125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT):

    BCT Effluent Limitations

    Stream Pollutant parameter BCT effluent limitations
    Produced Water (all facilities) Oil & Grease The maximum for any one day shall not exceed 72 mg/l and the 30-day average shall not exceed 48 mg/l.
    Drilling Fluids and Drill Cuttings and Dewatering Effluent:1
    All facilities except Cook Inlet No discharge.
    Cook Inlet:
    Water-based drilling fluids, drill cuttings, and dewatering effluent Free Oil No discharge.2
    Non-aqueous drilling fluids and dewatering effluent No discharge.
    Drill cuttings associated with non-aqueous drilling fluids Free Oil No discharge.2
    Well Treatment, Workover and Completion Fluids Free Oil No discharge.2
    Produced Sand No discharge.
    Deck Drainage Free Oil No discharge.3
    Sanitary Waste:
    Sanitary M10 Residual Chlorine Minimum of 1 mg/l maintained as close to this concentration as possible.
    Sanitary M91M Floating Solids No discharge.
    Domestic Waste Floating Solids and garbage No discharge of Floating Solids or garbage.

    [61 FR 66125, Dec. 16, 1996; 62 FR 1682, Jan. 13, 1997, as amended at 66 FR 6917, Jan. 22, 2001; 77 FR 29846, May 18, 2012]