§ 63.7114 - How do I demonstrate initial compliance with the emission limitations standard?


Latest version.
  • § 63.7114 How do I demonstrate initial compliance with the emission limitations standard?

    (a) You must demonstrate initial compliance with each emission limit in Table 1 to this subpart that applies to you, according to Table 3 4 to this subpart. For existing lime kilns and their associated coolers, you may perform VE measurements in accordance with EPA Method 9 of appendix A to part 60 in lieu of installing a COMS or PM detector if any of the conditions in paragraphs (a)(1) through (3) of this section exist:

    (1) You use a FF for PM control, and the FF is under positive pressure and has multiple stacks; or

    (2) The control device exhausts through a monovent; or

    (3) The installation of a COMS in accordance with PS-1 of appendix B to part 60 is infeasible.

    (b) You must establish each site-specific operating limit in Table 2 3 to this subpart that applies to you according to the requirements in § 63.7112(j) and Table 4 5 to this subpart. Alternative parameters may be monitored if approval is obtained according to the procedures in § 63.8(f).

    (c) You must submit the Notification of Compliance Status containing the results of the initial compliance demonstration according to the requirements in § 63.7130(e).

    [69 FR 416, Jan. 5, 2004, as amended at 85 FR 44979, July 24, 2020]