§ 75.56 - Certification, quality assurance and quality control record provisions.  


Latest version.
  • Link to an amendment published at 67 FR 40440, June 12, 2002.

    Before April 1, 2000, the owner or operator shall meet the requirements of either this section or § 75.59. On and after April 1, 2000, the owner or operator shall meet the requirements of § 75.59.

    (a) Continuous emission or opacity monitoring systems. The owner or operator shall record the applicable information in this section for each certified monitor or certified monitoring system (including certified backup monitors) measuring and recording emissions or flow from an affected unit.

    (1) For each SO2 or NOX pollutant concentration monitor, flow monitor, CO2 monitor, or diluent gas monitor, the owner or operator shall record the following for all daily and 7-day calibration error tests, including any follow-up tests after corrective action:

    (i) Component/system identification code;

    (ii) Instrument span;

    (iii) Date and hour;

    (iv) Reference value, (i.e., calibration gas concentration or reference signal value, in ppm or other appropriate units);

    (v) Observed value (monitor response during calibration, in ppm or other appropriate units);

    (vi) Percent calibration error (rounded to nearest tenth of a percent); and

    (vii) For 7-day calibration tests for certification or recertification, a certification from the cylinder gas vendor or CEMS vendor, that calibration gas as defined in § 72.2 and appendix A of this part, were used to conduct calibration error testing; and

    (viii) Description of any adjustments, corrective actions, or maintenance following test.

    (2) For each flow monitor, the owner or operator shall record the following for all daily interference checks, including any follow-up tests after corrective action:

    (i) Code indicating whether monitor passes or fails the interference check; and

    (ii) Description of any adjustments, corrective actions, or maintenance following test.

    (3) For each SO2 or NOX pollutant concentration monitor, CO2 monitor, or diluent gas monitor, the owner or operator shall record the following for the initial and all subsequent linearity check(s), including any follow-up tests after corrective action:

    (i) Component/system identification code;

    (ii) Instrument span;

    (iii) Date and hour;

    (iv) Reference value (i.e., reference gas concentration, in ppm or other appropriate units);

    (v) Observed value (average monitor response at each reference gas concentration, in ppm or other appropriate units);

    (vi) Percent error at each of three reference gas concentrations (rounded to nearest tenth of a percent); and

    (vii) Description of any adjustments, corrective action, or maintenance following test.

    (4) For each flow monitor, where applicable, the owner or operator shall record the following for all quarterly leak checks, including any follow-up tests after corrective action:

    (i) Code indicating whether monitor passes or fails the quarterly leak check; and

    (ii) Description of any adjustments, corrective actions, or maintenance following test.

    (5) For each SO2 pollutant concentration monitor, flow monitor, CO2 pollutant concentration monitor; NOX continuous emission monitoring system, SO2-diluent continuous emission monitoring system, and approved alternative monitoring system, the owner or operator shall record the following information for the initial and all subsequent relative accuracy tests and test audits:

    (i) Date and hour;

    (ii) Reference method(s) used;

    (iii) Individual test run data from the relative accuracy test audit for the SO2 concentration monitor, flow monitor, CO2 pollutant concentration monitor, NOX continuous emission monitoring system, SO2-diluent continuous emission monitoring system, or approved alternative monitoring systems, including:

    (A) Date, hour, and minute of beginning of test run,

    (B) Date, hour, and minute of end of test run,

    (C) Component/system identification code,

    (D) Run number,

    (E) Run data for monitor;

    (F) Run data for reference method; and

    (G) Flag value (0 or 1) indicating whether run has been used in calculating relative accuracy and bias values.

    (iv) Calculations and tabulated results, as follows:

    (A) Arithmetic mean of the monitoring system measurement values, reference method values, and of their differences, as specified in equation A-7 in appendix A to this part.

    (B) Standard deviation, as specified in equation A-8 in appendix A to this part.

    (C) Confidence coefficient, as specified in equation A-9 in appendix A to this part.

    (D) Relative accuracy test results, as specified in equation A-10 in appendix A to this part. (For the 3-level flow monitor test only, relative accuracy test results should be recorded at each of three gas velocities. Each of these three gas velocities shall be expressed as a total gross unit load, rounded to the nearest MWe or as steam load, rounded to the nearest thousand lb/hr.)

    (E) Bias test results as specified in section 7.6.4 in appendix A to this part.

    (F) Bias adjustment factor from equations A-11 and A-12 in appendix A to this part for any monitoring system or component that failed the bias test and 1.0 for any monitoring system or component that passed the bias test. (For flow monitors only, bias adjustment factors should be recorded at each of three gas velocities).

    (v) Description of any adjustment, corrective action, or maintenance following test.

    (vi) F-factor value(s) used to convert NOX pollutant concentration and diluent gas (O2 or CO2) concentration measurements into NOX emission rates (in lb/mmBtu), heat input or CO2 emissions.

    (vii) For flow monitors, the equation used to linearize the flow monitor and the numerical values of the polynomial coefficients or K factor(s) of that equation.

    (viii) The raw data and calculated results for any stratification tests performed in accordance with sections 6.5.6.1 through 6.5.6.3 in appendix A to this part.

    (ix) For moisture monitoring systems, the coefficient or “K” factor or other mathematical algorithm used to adjust the monitoring system with respect to the reference method.

    (6) [Reserved]

    (7) Results of all trial runs and certification tests and quality assurance activities and measurements (including all reference method field test sheets, charts, records of combined system responses, laboratory analyses, and example calculations) necessary to substantiate compliance with all relevant appendices in this part. This information shall include, but shall not be limited to, the following reference method data:

    (i) For each run of each test using method 2 in appendix A of part 60 of this chapter to determine volumetric flow rate:

    (A) Pitot tube coefficient;

    (B) Date of pitot tube calibration;

    (C) Average square root of velocity head of stack gas (inches of water) for the run;

    (D) Average absolute stack gas temperature, °R;

    (E) Barometric pressure at test port, inches of mercury;

    (F) Stack static pressure, inches of H2 O;

    (G) Absolute stack gas pressure, inches of mercury;

    (H) Moisture content of stack gas, percent;

    (I) Molecular weight of stack gas, wet basis (lb/lb-mole);

    (J) Number of reference method measurements during the run; and

    (K) Total volumetric flowrate (scfh, wet basis).

    (ii) For each test using method 2 in appendix A of part 60 of this chapter to determine volumetric flow rate:

    (A) Information indicating whether or not the location meets requirements of method 1 in appendix A of part 60 of this chapter;

    (B) Information indicating whether or not the equipment passed the leak check after every run included in the relative accuracy test;

    (C) Stack inside diameter at test port (ft);

    (D) Duct side height and width at test port (ft);

    (E) Stack or duct cross-sectional area at test port (ft2); and

    (F) Designation as to the load level of the test.

    (iii) For each run of each test using method 6C, 7E, or 3A in appendix A of part 60 of this chapter to determine SO2, NOX, CO2, or O2 concentration:

    (A) Run start date;

    (B) Run start time;

    (C) Run end date;

    (D) Run end time;

    (E) Span of reference method analyzer;

    (F) Reference gas concentration (low, mid-, and high gas levels);

    (G) Initial and final analyzer calibration response (low, mid- and high gas levels);

    (H) Analyzer calibration error (low, mid-, and high gas levels);

    (I) Pre-test and post-test analyzer bias (zero and upscale gas levels);

    (J) Calibration drift and zero drift of analyzer;

    (K) Indication as to which data are from a pretest and which are from a posttest;

    (L) Calibration gas level (zero, mid-level, or high); and

    (M) Moisture content of stack gas, in percent, if needed to convert to moisture basis of CEMS being tested.

    (iv) For each test using method 6C, 7E, or 3A in appendix A of part 60 of this chapter to determine SO2, NOX CO2, or O2 concentration:

    (A) Pollutant being measured;

    (B) Test number;

    (C) Date of interference test;

    (D) Results of interference test;

    (E) Date of NO2 to NO conversion test (method 7E only);

    (F) Results of NO2 to NO conversion test (method 7E only).

    (v) For each calibration gas cylinder used to test using method 6C, 7E, or 3A in appendix A of part 60 of this chapter to determine SO2, NOX, CO2, or O2 concentration:

    (A) Cylinder gas vendor name from certification;

    (B) Cylinder number;

    (C) Cylinder expiration date;

    (D) Pollutant(s) in cylinder; and

    (E) Cylinder gas concentration(s).

    (b) Excepted monitoring systems for gas-fired and oil-fired units. The owner or operator shall record the applicable information in this section for each excepted monitoring system following the requirements of appendix D of this part or appendix E of this part for determining and recording emissions from an affected unit.

    (1) For each oil-fired unit or gas-fired unit using the optional procedures of appendix D of this part for determining SO2 mass emissions and heat input or the optional procedures of appendix E of this part for determining NOX emission rate, for certification and quality assurance testing of fuel flowmeters:

    (i) Date of test,

    (ii) Upper range value of the fuel flowmeter,

    (iii) Flowmeter measurements during accuracy test,

    (iv) Reference flow rates during accuracy test,

    (v) Average flowmeter accuracy as a percent of upper range value,

    (vi) Fuel flow rate level (low, mid-level, or high); and

    (vii) Description of fuel flowmeter calibration specification or procedure (in the certification application, or periodically if a different method is used for annual quality assurance testing).

    (2) For gas-fired peaking units or oil-fired peaking units using the optional procedures of appendix E of this part, for each initial performance, periodic, or quality assurance/quality control-related test:

    (i) For each run of emissions data;

    (A) Run start date and time;

    (B) Run end date and time;

    (C) Fuel flow (lb/hr, gal/hr, scf/hr, bbl/hr, or m3/hr);

    (D) Gross calorific value (heat content) of fuel (Btu/lb or Btu/scf);

    (E) Density of fuel (if needed to convert mass to volume);

    (F) Total heat input during the run (mmBtu);

    (G) Hourly heat input rate for run (mmBtu/hr);

    (H) Response time of the O2 and NOX reference method analyzers;

    (I) NOX concentration (ppm);

    (J) O2 concentration (percent O2);

    (K) NOX emission rate (lb/mmBtu); and

    (L) Fuel or fuel combination (by heat input fraction) combusted.

    (ii) For each unit load and heat input;

    (A) Average NOX emission rate (lb/mmBtu);

    (B) F-factor used in calculations;

    (C) Average heat input rate (mmBtu/hr);

    (D) Unit operating parametric data related to NOX formation for that unit type (e.g., excess O2 level, water/fuel ratio); and

    (E) Fuel or fuel combination (by heat input fraction) combusted.

    (iii) For each test report;

    (A) Graph of NOX emission rate against heat input rate;

    (B) Results of the tests for verification of the accuracy of emissions calculations and missing data procedures performed by the automated data acquisition and handling system, and the calculations used to produce NOX emission rate data at different heat input conditions; and

    (C) Results of all certification tests and quality assurance activities and measurements (including reference method field test sheets, charts, laboratory analyses, example calculations, or other data as appropriate), necessary to substantiate compliance with the requirements of appendix E of this part.

    (c) For units with add-on SO2 and NOX emission controls following the provisions of § 75.34(a)(1) or (a)(2), the owner or operator shall keep the following records on-site in the quality assurance/quality control plan required by section 1 in appendix B of this part:

    (1) A list of operating parameters for the add-on emission controls, including parameters in § 75.55 (b), appropriate to the particular installation of add-on emission controls; and

    (2) The range of each operating parameter in the list that indicates the add-on emission controls are properly operating.

    Effective Date Note:

    At 67 FR 40440, June 12, 2002, § 75.56 was removed and reserved, effective July 12, 2002.